Desa RCLP50-F owner manual Theory Of Operation, Ventilation, Assembly

Models: RCLP50-F

1 44
Download 44 pages 39.32 Kb
Page 4
Image 4
THEORY OF OPERATION

THEORY OF OPERATION

The Fuel System: The hose/regulator assembly attaches to the propane gas supply. This provides fuel to the heater.

The Air System: The motor turns the fan. The fan pushes air into and around the combustion chamber. This air is heated and provides a stream of clean, hot air.

The Ignition System: The piezo ignitor lights the burner.

The Automatic Control System: This system causes the heater to shut down if the flame goes out.

Combustion Chamber

Clean Heated VENTILATION Air Out (Front)

ASSEMBLY Air For Combustion

Fan

Motor

Cool Air In (Back)

Hose/

Regulator

Assembly

Manual background Air For Heating

Figure 2 - Cross Section Operational View

VENTILATION

WARNING: Provide at least

a 1.5 ft

2

(0.14 m

) opening of

 

2

 

fresh, outside air while running

heater. If proper fresh, outside

air ventilation is not provided,

carbon monoxide poisoning

can occur. Provide proper fresh,

outside

 

air ventilation before

running heater.

 

 

 

ASSEMBLY

1.Remove screw from top of fan guard. Discard screw.

2.Insert nut clip (provided with handle) with flat side facing up through slot in top of shell. Align holes in nut clip with screw hole behind slot in top of shell. (see Figure 4).

Manual backgroundManual background Remove

Screw

3.

Place handle over hole and clip. Insert two

 

screws (provided with handle) through handle

 

and tighten into shell. Make sure rear screw

 

goes through shell and into fan guard. Tighten

 

screws firmly.

Nut Clip

 

 

 

 

 

 

Slot

Shell

 

 

 

Flat Side Facing Up

 

 

Figure 4 - Installing Nut Clip

 

Screws

 

Handle

 

Rear of

Nut Clip

Heater

 

Figure 3 - Removing Screw from Top of

 

Fan Guard

Figure 5 - Attaching Handle

4

www.desatech.com

105339-01C

Page 4
Image 4
Desa RCLP50-F owner manual Theory Of Operation, Ventilation, Assembly