Desa REM200T Spark Plug, Nozzle, 200,000 BTU/HR PORTABLE FORCED AIR HEATER, Service Procedures

Models: REM200T

1 16
Download 16 pages 33.17 Kb
Page 10
Image 10
SPARK PLUG

200,000 BTU/HR

PORTABLE FORCED AIR HEATER

SERVICE

PROCEDURES

Continued

SPARK PLUG

1.

Remove upper shell (see page 8).

2.

Remove fan (see page 8).

3.

Remove spark plug wire from spark plug.

4.

Remove spark plug and wave spring

 

washer from burner head using 13/16"

 

open-end wrench.

5.

Clean and regap spark plug electrodes

 

to .110 gap.

6.

Install spark plug and wave spring

 

washer in burner head. Torque 40 to 60

 

inch-pounds. Then adjust (if necessary)

 

to bring side electrode into the accept-

NOZZLE

1.Remove upper shell (see page 8).

2.Remove fan (see page 8).

3.Remove fuel and air line hoses from burner head.

4.Remove spark plug wire from spark plug.

5.Remove spark plug from burner head using 13/16" open-end wrench.

6.Remove three screws using 5/16" nut- driver and remove burner head from combustion chamber.

7.Place burner head into vise and lightly tighten.

8.Carefully remove nozzle from burner head using 5/8" socket wrench (see Fig- ure 16, page 11).

9.Blow compressed air through face of nozzle. This will free any dirt in nozzle area.

10.Inspect nozzle seal for damage.

11.Replace nozzle into burner head and tighten firmly (80-110 inch-pounds).

12.Attach burner head to combustion chamber.

13.Install spark plug in burner head.

14.Attach spark plug wire to spark plug.

15.Attach fuel and airline hoses to burner head.

16.Replace fan (see page 8).

17.Replace fan guard and upper shell.

 

able range (see Figure 14).

7.

Attach spark plug wire to spark plug.

8.

Replace fan (see page 8).

9.

Replace fan guard and upper shell.

Burner Head

Wave Spring

 

 

Washer

Spark

Plug Spark Plug

Wire

Combustion

Chamber

Burner Head

Spark Plug Wire

Wave Spring

Washer

 

Spark

Screw

Plug

 

Air Line Hose

Fuel Line Hose

 

Figure 15 - Removing Burner Head

 

Figure 12 - Spark Plug Removal

Bend Here to

Adjust Gap

NOZZLE Gap

Figure 13 - Spark Plug Gap

Side Electrode

270° Acceptable Range For Side Electrode

Figure 14 - Acceptable Range For Side Electrode

10

106068

Page 10
Image 10
Desa REM200T owner manual Spark Plug, Nozzle, 200,000 BTU/HR PORTABLE FORCED AIR HEATER, Service Procedures, Continued