TROUBLESHOOTING

OWNER’S MANUAL

TROUBLESHOOTING

Note: For additional help, visit DESA International’s Technical Service web site at www.desatech.com.

OBSERVED FAULT WARNING: Never service heater while it is plugged in, operat- ing, or hot. Severe burns and electrical shock can occur.

OBSERVED FAULT

POSSIBLE CAUSE

REMEDY

Heater ignites, but flame-out control shuts

1.

Wrong pump pressure

1.

See Pump Pressure Adjustment, page 9

off heater after a short period of time

2.

Dirty air output, air intake and lint filters

2.

See Air Output, Air Intake and Lint Fil-

 

 

 

 

 

ters, page 8

 

3.

Dirty fuel filter

3.

See Fuel Filter, page 9

 

4.

Dirt in nozzle

4.

See Nozzle, page 10

 

5.

Dirty photocell lens

5.

Clean photocell lens

 

6.

Bad flame-out control

6.

Replace flame-out control

 

 

 

 

 

 

 

Heater will not ignite, but motor runs for a

1.

Wrong pump pressure

1.

See Pump Pressure Adjustment, page 9

short period of time

2.

Improper spark plug gap/position or

2.

See Spark Plug, page 10

 

 

carbon deposits across gap.

 

 

 

 

3.

Dirty fuel filter

3.

See Fuel Filter, page 9

 

4.

Dirt in nozzle

4.

See Nozzle, page 10

 

5.

Water in fuel tank

5.

Drain and flush fuel tank with clean

 

 

 

 

 

kerosene. See Storing, Transporting, or

 

 

 

 

 

Shipping, page 6

 

6.

Bad fuel valve

6.

See Fuel Valve, page 9

 

 

 

 

 

 

 

 

WARNING: High voltage!

 

 

 

 

 

 

 

 

 

7.

Electronic ignitor not grounded

7.

Make sure electronic ignitor mounting

 

 

 

 

 

is tight

 

8.

Bad electronic ignitor

8.

Replace electronic ignitor

 

 

 

 

 

Motor does not start when heater is plugged

1.

Flame-out control not reset

1.

Press flame-out control reset button

in, fan rotates slowly or does not turn

2.

Thermostat setting is too low

2.

Turn thermostat knob to a higher setting

 

3.

Solid state relay not allowed to reset

3.

Wait two minutes before trying to restart

 

 

 

 

 

heater

 

4.

Binding pump rotor

4.

If fan is hard to turn, see Pump Rotor,

 

 

 

 

 

page 11