TROUBLESHOOTING AND MAINTENANCE SERVICE
Check the following points before calling for services:
Warning | Caution |
|
|
Disassembling and repair should be carried | Cut off the power supply and closed the feed |
out only by qualified technicians. | valve when there is no water. |
Unauthorized disassemble and improper re- | In case the feed valve is not closed in time, |
pair may be | Caution |
the water may get dirty when it is fed into the | |
shock or conflagration. | dishwasher next time. |
|
|
When alarm signal occurs
1)Shut off the power supply and the pilot lamp goes off and the buzzer stops. 2)Make troubleshooting according to the following information.
| Disorder | Possible causes | Trouble | |
|
|
|
|
|
|
| No water supply | * Turn on the tap. | |
| The indicators for drying, | * The tap is turned off. | * Shut off the power supply. Wash the | |
| prewash and normal wash illu- | * There is no water in the pipe. | dishes when there is water supply. | |
| minate and the buzzer buzzes. | * The pipe is blocked. | * Clean the pipe. | |
|
| * The water pressure is too low. | * Wait about 1minute. | |
|
|
|
|
|
| The indicators for drying, nor- | Little drain water |
|
|
|
|
|
| |
| mal wash and intensive wash | * The drainage pipe is twisted, blocked and no drainage. | * Arrange the drainage pipe. | |
| illuminate and the | * Part of the drainage pipe is 10cm higher than the | * Lower the drainagepipe. | |
| buzzes. | operation surface. |
|
|
|
| * The filter screen is dirty. | * Take out the filter and clean it. | |
|
|
|
|
|
| The indicators for drying, | Improper lock | * Lock the door properly. | |
| prewash and normal wash illu- | * The door is not closed properly. | ||
| * Closed the door. | |||
| minate and the buzzer buzzes. | * The door is opened during operation. | ||
|
|
| ||
|
|
|
|
|
| Other illuminate of pilot lamp | * Malfunction of the control system. | * Contact service center. | |
| and buzz alarm. | |||
|
|
|
| |
|
|
|
|
|
3)Do not operate the unit until it becomes normal.
4)If abnormal phenomena occur once more, take off the plug and make contact with the local
maintenance department.
KNPK | GB |