Install and use stove and burner system with care. Follow all local codes. In the absence to local codes, use the current National Fuel Gas Code ANSI Z223.1/NFPA 54* (USA) or the current CAN/CGA- B149[.1 or .2] Installation Codes (Canada).

*Available from:

American National Standards Institute, Inc.

1430 Broadway

New York, NY 10018

National Fire Protection Association, Inc.

Batterymarch Park

Quincy, MA 02269

PRODUCT FEATURES

OPERATION

This B-vent cast iron stove with burner system is clean burning and vents vertically. Heat is generated by both realistic flames and glowing embers. When used without the blower accessory, the stove with burner system requires no electricity making it ideal for emergency backup heat.

PIEZO IGNITOR

This burner system has a piezo ignitor. This system requires no matches, batteries, or other sources to light burner system.

PRE-INSTALLATION

PREPARATION

WARNING: A qualified installer or service person must install stove and burner system. Follow all local codes.

CAUTION: This stove with burner system creates warm air currents. These currents move heat to wall surfaces next to stove. Installing stove next to vinyl or cloth wall coverings or operating stove with burner system where impurities (such as, but not limited to, tobacco smoke, aromatic candles, cleaning fluids, oil or kerosene lamps, etc.) in the air exist, may discolor walls or cause odors.

LOCATION AND SPACE REQUIREMENTS

Determine the safest and most efficient location for your DESA B-vent cast iron stove. Make sure that rafters and wall studs are not in the way of the venting system. Choose a location where the heat output is not affected by drafts, air conditioning ducts, windows, or doors. Figure 2 shows some common locations. Read all venting information in this manual. Be aware of all restrictions and precautions before deciding the exact location for your stove.

When deciding the location of your stove, follow these rules:

1.Do not connect this stove and burner system to a chimney flue serving a separate solid-fuel burning fireplace or appliance.

2.Due to high temperatures, do not locate this stove in high traf- fic areas or near furniture or draperies.

3.Proper clearances must be maintained, see Figure 3 below and Figure 4 on page 5.

4.This stove is a freestanding unit designed to set directly on the floor. If your stove is to be installed directly on carpeting, vi- nyl tile, or any combustible material other than wood, it must be installed on a metal or wood panel extending the full width and depth of the stove. See Figure 5, page 5.

On Wall with Vertical

Corner Installation with Vertical

Termination Through Ceiling

Termination Through Ceiling

Figure 2 - Common Stove Locations

Ceiling

42"

36"

 

 

 

 

 

 

 

 

 

 

 

4"

from

 

 

 

 

 

 

 

 

 

 

 

from

Front

 

 

 

 

 

 

Back

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Wall

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Floor

29"

4"

6"

Front

Figure 3 - Clearances for Standard Installation