CAST IRON STOVE AND
Installing
Installing Optional Blower Accessory
7
CAST IRON STOVE AND B-VENT BURNER SYSTEM ASSEMBLY
Continued
INSTALLING B-VENT BURNER SYSTEM INTO STOVE BODY
1.Carefully lift burner system and place into stove body from the rear of stove.
2.Place the left and right grate tops into the top of stove body. Dis- card center grate top of stove and replace with center grate top provided with burner system.
Center Top Grate | Right Top Grate |
(Included with | |
Burner System) |
|
Left Top |
|
Grate |
|
Cast Iron
Stove Body
Burner
System
Figure 15 - Installing Burner System Into Cast Iron Stove Body
INSTALLING OPTIONAL BLOWER
ACCESSORY
NOTICE: If installing blower in an existing stove burner system with gas connections, shut off gas supply and disconnect heater from gas supply. Con- tact a qualified service person to do this.
1.Remove 4 hex screws securing rear cover to back of stove body (see Figure 16).
2.Separate bottom cover from rear cover by loosening the 8 mounting screws (see Figure 16).
3.Align the holes in the top mounting tabs of blower with the holes in wall of rear cover. Using the 4 screws provided, mount blower and tighten screws securely (see Figure 17).
4.Thermostat Blower Only: Attach thermal switch and bracket to inside rear cover wall with two hex head screws provided as shown in Figure 17. After securing bracket to rear cover, carefully bend along existing bend line on bracket to almost a 90° angle (see Figure 17). This will allow thermal switch to be positioned against stove rear wall and sense temperature when in operating mode.
Hex Screws
Rear Cover
Stove Body
Mounting
Screws
Mounting
Screws
Bottom Cover
Figure 16 - Removing Rear Cover and Bottom Cover from Stove Body
Speed
BlowerControl
Control
Knob Locknut
TOP VIEW
Control Shaft
| Screws |
Thermal Switch |
|
and Bracket |
|
Mounting Holes |
|
Blower |
|
Assembly | Mounting Holes |
|
Figure 17 - Blower Assembly, Speed Control, and Thermal Switch Locations