Desa SMS24, SMS18 installation manual Installation, Flue Opening Specifications, Check Gas Type

Models: SMS24 SMS18

1 16
Download 16 pages 20.36 Kb
Page 5
Image 5
INSTALLATION

INSTALLATION

FLUE OPENING SPECIFICATIONS WARNING: Before installing in a solid fuel burning fireplace, the chimney flue and firebox must be cleaned of soot, creo- sote, ashes and loose paint by a qualified chimney cleaner. Creo- sote will ignite if highly heated. A dirty chimney flue may create and distribute soot within the house. Inspect chimney flue for damage. If damaged, repair flue before operating appliance.

NOTICE:Installation,service,and repair of this appliance must be performedbyaqualifiedinstaller, service agency, company or gas supplier experienced with this type of gas appliance. Only factory authorized components listed in these instructions may be used in accordance with the manufacturer’s instructions and all codes and requirements of the authority having jurisdiction. Any modifications to this kit, or use of unauthorized components or accessory items will void the manufacturer’swarranty,andmay result in a hazardous condition.

FLUE OPENING SPECIFICATIONS

Note: This vented appliance must be installed only in a solid-fuel burning fireplace with a working flue and constructed of noncombustible material.

The charts in Figure 2 indicate technical information regarding the installation of your gas log set. Please make sure that all of the specifications shown are applicable before installation is attempted.

The fireplace must include a working flue and venting system with the minimum openings shown in the Figure 2.

 

 

 

Burner

Btu Input

 

Minimum

 

 

 

Descrip-

Natural

 

 

Vent

Model

 

tion

 

 

Gas

 

Opening

 

 

 

 

 

 

 

 

 

 

 

SMS18

 

18" Ramp

60,000

 

 

8" dia.

SMS24

 

24" Ramp

80,000

 

 

8" dia.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MINIMUM FIREBOX SIZES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MODEL

 

FRONT

 

BACK

 

DEPTH

HEIGHT

 

 

 

WIDTH

 

WIDTH*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SMS18

28"

 

18"

 

 

16"

 

 

18"

SMS24

32"

 

24"

 

 

16"

 

 

18"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*At depth indicated

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FUEL INLET PRESSURE

 

 

 

SPECIFICATIONS (W.C.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Min.

 

 

 

 

Max.

 

 

NG

 

5.5"

 

 

10.5"

 

 

 

LP

 

11"

 

 

13"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BURNER ORIFICE

 

 

 

 

LOG

 

 

NATURAL

 

 

 

 

SIZE

 

 

 

 

 

 

 

 

 

 

 

 

IN.

 

 

NUM.

 

 

 

18"

 

.120

 

 

31

 

 

 

 

24"

 

.140

 

 

28

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 2 - Technical Information Charts

CHECK GAS TYPE

Use only natural gas. If your gas supply is not natural gas, you must install ON/OFF Safety Valve/Pilot Kit (see Accessories, page 13). Call dealer where you bought log set.

If the fireplace does not have a gas supply shutoff valve, one must be installed.

VENTING SPECIFICATIONS FOR INSTALLATION

The fireplace chimney flue and vent must be draft- ing properly. To check the vent for proper drafting: Light a tightly rolled newspaper on one end and place it at the inside front edge of the fireplace. Observe the smoke and be sure the vent is properly drawing it up the chimney. If the smoke spills out into the room, extinguish the flame and remove any obstruction until proper venting is achieved.

The chimney flue must remain open a minimum of 3" at all times during the operation of this log set.

117536-01B

www.desatech.com

5

Page 5
Image 5
Desa SMS24, SMS18 Flue Opening Specifications, Check Gas Type, Venting Specifications For Installation