Desa SMS18 WARNING Never check for gas leaks with open flame, Continued, Testing Burner For Leaks

Models: SMS24 SMS18

1 16
Download 16 pages 20.36 Kb
Page 8
Image 8
OPTIONAL GA9200 SERIES ON/OFF SAFETY VALVE/PILOT KIT

INSTALLATION

Continued

OPTIONAL GA9200 SERIES ON/OFF SAFETY VALVE/PILOT KIT

For additional convenience and safety an optional ON/OFF safety valve/pilot kit is available. See Ac- cessories, page 13.

Parts are available in this kit for propane/LP conver- sion. See kit instruction sheet for detailed installation instructions.

TESTING BURNER FOR LEAKS WARNING: You must use an ON/OFF safety valve/pilot kit for propane/LP conversion.

TESTING BURNER FOR LEAKS

1.Generously apply noncorrosive leak detec- tion fluid to all connections.

 WARNING: Never check for gas leaks with open flame. WARNING: Never check for gas leaks with open flame.

3.Place two front logs onto grate (see Figure 8).

4.Place back log on grate steps (see Figure 8).

5.Figure 8 and Figure 9 on page 9 show a recom- mended log arrangement, however you may arrange the logs as you wish. Leave as much open space as possible to minimize flame im- pingement and sooting. Note: Logs may chip if they are handled roughly or if hit together while being placed.

5.Place ember chunks onto bottom portion of ramp burner using Figure 9, page 9, as an example.

Figure 7 - Attaching Grate StepsADDING PAN MATERIALGrate Steps

Figure 7 - Attaching Grate Steps

2.Light the burner with the shutoff valve no more than half open and holding a match

slightly in front of the pan (see Lighting Instructions, page 9).

3. Inspect all connections for bubbles, raw gas odor, or flame from any area other than the burner (leaks). If leaks are detected, shut off the gas valve immediately. Tighten, or reas- semble the loose connection(s) using pipe joint compound until burner system is leak free.

4. When the burner is tested and leak free, observe the individual tongues of flame on the burner. Make sure that all ports are clear and produc- ing flame evenly across the burner. If any ports appear blocked, clear them by removing the burner manifold and reaming the ports with a modified paper clip or other suitable tool.

5.When finished testing, turn the gas shutoff valve OFF to extinguish all flames.

ADDING PAN MATERIAL

Open the bag of glowing embers and spread it evenly over the burner ramp.

INSTALLING THE GRATE AND LOGS

1. Slide grate steps onto the ends of the grate as shown in Figure 7.

2. Place the grate over the burner pan where the

 

two outer horizontal supports on the grate fit

 

into the two pan positioning tabs on the outer

 

edges of the pan.

Figure 8 - Installing Logs

8

www.desatech.com

117536-01B

Page 8
Image 8
Desa SMS18 WARNING Never check for gas leaks with open flame, Continued, Testing Burner For Leaks, Adding Pan Material