SAFETY INFORMATION
Continued
16.Use only soapy water (1 part liquid dishwash- ing detergent to 3 parts water) to conduct leak tests whenever a propane cylinder is connected. Bubbles indicate a leak.
17.Do not adjust gas regulator. If you are unsure of your appliances gas type or pressure, call a qualified service person.
18.Place the control knob on "OFF" position when heater is not in use.
19.Always disconnect the gas supply after the heater is turned "OFF".
20.Do not move, handle or service while hot or burning.
21.Allow 45 minutes to cool down after use before attempting to move heater.
22.Do not operate this appliance in windy condi- tions. Maximum allowable wind speed is 10 mph (16 Km/h).
23.Do not operate this appliance in temperature conditions below 40° F (5° C).
24.Keep heater away from areas where flammable liquids, vapors or solids are stored or used.
25.If operated in salt air environments, the unit will require more frequent cleaning; otherwise, the longevity of the unit will deteriorate rapidly. Use warm soapy water to clean the unit.
26.Items or material, when stored under the heater, will be subjected to radiant heat and could be seriously damaged.
27.Use only in accordance with local codes, or in the absence of local codes, with the National Fuel Gas Code ANSI Z223.1.
Any guard or other protective device removed for servicing must be re- placed prior to operating the heater.
Surface temperatures become very hot when operating heater. Children and adults should stay away to avoid burns or clothing ignition.
Young children should be carefully supervised when they are in the area of the heater.
Clothing or other flammable mate- rials should not be hung from the heater, or placed on or near heater.
Installation and repair should be done by a qualified service person. The heater should be inspected before use and at least annually by a qualified service person. More frequent cleanings may be required as necessary. It is imperative that control compartments, burners and circulating air passageways of the heater be kept clean.
CAUTION: The gas pressure regulator provided with this ap- pliance must be used. This regu- lator is set for an output pressure of 11" W.C. (2.74 kPa).
PROPANE/LP SAFETY
WARNING: For outdoor use only.
ASPHYXIATION HAZARD
•Do not use this heater for heating human living quarters.
•Do not use in unventilated areas.
•The flow of combustion and ventilation air must not be obstructed.
•Proper ventilation air must be provided to support the combustion air require- ments of the heater being used.
•Refer to the Specifications, page 2, heater data plate or contact DESA Heating Prod- ucts to determine combustion air ventila- tion requirements of the heater.
•Lack of proper ventilation air will lead to improper combustion.
•Improper combustion can lead to carbon monoxide poisoning leading to serious injury or death. Symptom of carbon mon- oxide poisoning can include headaches dizziness and difficulty in breathing.
4 | www.desatech.com |