CLEANING AND

MAINTENANCE

Continued

8.Apply air pressure into the venturi tube (with cone on end) to remove dust, lint or spider webs.

9.Reinstall burner assembly to base assembly.

CABINET

Air Passageways

Use a vacuum cleaner or pressurized air to clean.

Exterior

Use a soft cloth dampened with a mild soap and water mixture. Wipe the cabinet to remove dust.

STORAGE

1.Allow at least 45 minutes for heater to cool down after using.

2.Store heater upright in a sheltered area away from inclement weather and dust.

3.If desired, cover heater after heater has cooled.

4.If heater is not to be used for an extended period of time, disconnect and remove propane/LP gas cylinder and store in accordance with the Standard for Storage and Handling of Liquefied Petroleum Gases, ANSI/INFPA 58.

SERVICING

To assure safety, proper function and longevity of the heater, regular maintenance is required. The frequency of maintenance will depend on the usage of the unit. Review the following concern- ing the criteria for a properly functioning heater. Failing to follow proper, regular maintenance will void warranty.

A hazardous condition may result if a heater is used that has been modified or is not functioning properly. When the heater is working properly:

The flame is contained within the heater.

The flame is essentially blue with perhaps some yellow tipping.

There is no strong disagreeable odor, eye burn- ing or other physical discomfort.

There is no smoke or soot internal or external to the heater.

There are no unplanned or unexplained shut downs of the heater.

The parts lists and wiring diagram show the heater as it was constructed. Do not use a heater which is different from that shown. In this regard, use only the hose, regulator and cylinder connection fitting (called a POL fitting) supplied with the heater. IMPORTANT: Do not use alternates. For this heater, the regulator must be set as shown in Speci- fications, page 2. If there is any uncertainty about the regulator setting, have it checked.

8

www.desatech.com

114082-01A