OPERATING HEATER
Continued
THERMOSTAT CONTROL
OPERATION
The thermostatic control used on these models differs from standard thermostats. Standard thermostats simply turn on and off the burner. The thermostat used on this heater senses the room temperature. At times the room may exceed the set temperature. If so, the burner will shut off. The burner will cycle back on when room temperature drops below the set temperature. The control knob can be set to any heat level between 1 and 5. This adjusts the amount of gas flow to the burner that increases or decreases the burner flame height. Note: The thermostat sensing bulb measures the temperature of air near the heater cabinet. This may not always agree with room tem- perature (depending on housing construction, installation location, room size, open air tem- peratures, etc.) Frequent use of your heater will let you determine your own comfort levels.
MANUAL LIGHTING
PROCEDURE
1.Remove front panel (see Figure 10, page 9).
2.Follow steps 1 through 7 under Lighting Instructions, page 13.
3.With control knob pressed in, strike match. Hold match to pilot until pilot lights.
4.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Now follow step 9, under Lighting Instructions, page 13.
5.Replace front panel.
INSPECTING HEATER
Check pilot flame pattern and burner flame pat- tern often.
PILOT FLAME PATTERN
Figure 18 shows a correct pilot flame pattern. Figure 19 shows an incorrect pilot flame pattern. The incor- rect pilot flame is not touching the thermocouple. This will cause the thermocouple to cool. When the thermocouple cools, the heater will shut down.
If pilot flame pattern is incorrect, as shown in Figure 19
•turn heater off (see To Turn Off Gas to Ap- pliance, page 13)
•see Troubleshooting, page 16
Note: The pilot flame on natural gas units will have a slight curve, but flame should be blue and have no yellow or orange color.
Thermocouple | Blue Pilot Flame |
| |
| Pilot Burner |
Figure 18 - Correct Pilot Flame Pattern
Thermocouple
Yellow Pilot Flame
Pilot Burner
Figure 19 - Incorrect Pilot Flame Pattern
BURNER FLAME PATTERN
WARNING: If yellow tipping occurs, your heater could pro- duce increased levels of carbon monoxide.
NOTICE: Do not mistake orange flames with yellow tipping. Dirt or other fine particles enter the heater and burn causing brief patches of orange flame.