INSPECTING HEATER

Continued

Figure 20 shows a correct burner flame pattern. Figure 21 shows an incorrect burner flame pattern. The incorrect burner flame pattern shows yellow tipping of the flame.

If burner flame pattern is incorrect, as shown in Figure 21

turn heater off (see To Turn Off Gas to Appli- ance, page 14)

see Troubleshooting, page 16

 

Blue

 

Flame

Figure 20 - Correct Burner Flame Pattern

Yellow

Tipping

Figure 21 - Incorrect Burner Flame Pattern

CLEANING AND

MAINTENANCE

WARNING: Turn off heater and let cool before cleaning.

CAUTION: You must keep control areas, burner and circu- lating air passageways of heater clean. Inspect these areas of heater before each use. Have heater inspected yearly by a qualified service person. Heater may need more frequent clean- ing due to excessive lint from carpeting, bedding material, pet hair, etc.

WARNING: Failure to keep the primary air opening(s) of the burner(s) clean may result in sooting and property damage.

ODS/PILOT AND BURNER

Use a vacuum cleaner, pressurized air or small, soft bristled brush to clean.

BURNER PILOT AIR INLET

The primary air inlet holes allow the proper amount of air to mix with the gas. This provides a clean burning flame. Keep these holes clear of dust, dirt and lint. Clean these air inlet holes prior to each heating season. Blocked air holes will create soot. We recommend that you clean the unit every three months during operation and have heater inspected yearly by a qualified service person.

We also recommend that you keep the burner tube and pilot assembly clean and free of dust and dirt. To clean these parts we recommend using compressed air no greater than 30 PSI. Your local computer store, hardware store or home center may carry compressed air in a can. You can use a vacuum cleaner in the blow position. If using com- pressed air in a can, please follow the directions on the can. If you donʼt follow directions on the can, you could damage the pilot assembly.

1.Shut off the unit, including the pilot. Allow the unit to cool for at least thirty minutes.

2.Inspect burner, pilot for dust and dirt.

3.Blow air across the ports/slots and holes in the burner.

4.Never insert objects into the pilot tube.

Clean the pilot assembly also. A yellow tip on the pilot flame indicates dust and dirt in the pilot as- sembly. There is a small pilot air inlet about two inches from where the pilot flame comes out of the pilot assembly (see Figure 22). With the heater off, lightly blow air through the air inlet. You may blow through a drinking straw if compressed air is not available.

Pilot Assembly

Pilot Air Inlet

Figure 22 - Pilot Air Inlet

CABINET

Air Passageways Use a vacuum cleaner or pressurized air to clean.

Exterior Use a soft cloth dampened with a mild soap and water mixture. Wipe the cabinet to remove dust.

116307-01B

www.desatech.com

15

Page 15
Image 15
Desa VSFG20NT, SPC20PT, SPC20NT, LSF30NT, LSF20NT Cleaning Maintenance, ODS/PILOT and Burner, Burner Pilot AIR Inlet, Cabinet