Desa SF20PT, SPC20PT, SPC20NT, LSF30NT, SF30PT Installation, AdjoiningWall, Connecting To Gas Supply

Models: SF30NT REM20PT VSFG20PT REM20NT LSFG20PT VSF20NT SF20PT LSF20PT SFG20PT LSF20NT VSF30NT VSF20PT SFG20NT LSF30NT VSFG20NT SF30PT LSF30PT SPC20NT SPC20PT

1 48
Download 48 pages 22.8 Kb
Page 9
Image 9
AdjoiningWall

INSTALLATION

Continued

Decide which method better suits your needs. Either method will provide a secure hold for the heater.

Marking Screw Locations

CONNECTING TO GAS SUPPLY WARNING: Maintain mini- mum clearances shown in Figure 4. If you can, provide greater clearances from floor and joining wall.

Mark three screw locations on wall as shown in Figure 6).

5.Insert mounting screws into wall anchors.

6.Tighten screws until screw head is 1/8" away from wall.

Figure 7 - Folding

Figure 8 - Popping

Anchor

Open Anchor Wings

 

For Thin Walls

Placing Heater On Mounting Screws

1.Locate two top vertical key slots on back end panels of heater.

2.Place heater onto mounting screws.

AdjoiningWall

7"

Min.

9"

Min.

20,000 Btu Heaters

167/8"

30,000 Btu Heaters

245/16"

Insert

Mounting 18 3/4"

Screws Min.

Vertical

Manual backgroundManual background Key Slots Manual backgroundManual background

Floor

Figure 6 - Wall Mounting Clearances

Locate hardware packet behind left side door of heater.

Attaching To Wall Stud Method For attaching heater to wall studs

1.Drill holes at marked locations using 9/64" drill bit. Holes must be level to prevent com- plications with front panel.

2.Tighten screws until screw head is 1/8" away from wall.

Attaching To Wall Anchor Method

For attaching heater to hollow walls (wall areas be- tween studs) or solid walls (concrete or masonry).

1.Drill holes at marked locations using 5/16" drill bit. Holes must be level to prevent com- plications with front panel. For solid walls (concrete or masonry), drill at least 1" deep.

2.Fold wall anchor as shown in Figure 7.

3.Insert wall anchor (wings first) into hole. Tap anchor flush to wall.

4.For thin walls (1/2" or less), insert red key into wall anchor. Push red key to “pop” open anchor wings. IMPORTANT: Do not hammer key! For thick walls (over 1/2" thick) or solid walls, do not pop open wings.

Figure 9 - Vertical Key Slots for Mounting

Heater to Wall

CONNECTING TO GAS SUPPLY

Manual background WARNING: This appliance requires a 3/8" NPT (National Pipe Thread) inlet connection to the pressure regulator.

Manual background WARNING: A qualified service personmustconnectheatertogas supply. Follow all local codes.

Manual background WARNING: For natural gas, never connect heater to private (non-utility) gas wells. This gas is commonly known as wellhead gas.

IMPORTANT: For natural gas, check gas line pressure before connecting heater to gas line. Gas line pressure must be no greater than 10.5" of wa- ter. If gas line pressure is higher, heater regulator damage could occur.

116307-01B

www.desatech.com

9

Page 9
Image 9
Desa SPC20PT, SPC20NT, LSF30NT, LSF20NT, LSF20PT, LSFG20PT, LSF30PT Installation, AdjoiningWall, Connecting To Gas Supply