OWNER’S MANUAL
INSTALLATION
Continued
10.Carefully insert fireplace into cabinet man- tel. Be careful not to scratch or damage hearth base, cabinet mantel, or any lami- nate trim on hearth base. Remove protec- tive material from top of hearth base and from front of fireplace (if any). Note:You can secure fireplace to hearth or floor. Open lower louver. Locate screw holes in bottom of base. Tighten wood screws through these holes and into hearth or floor.
11.Attach gas line from fireplace gas regu- lator to gas supply. See Connecting Fireplace to Gas Supply, page 11.
12.Check all gas connections for leaks. See Checking Gas Connections, page 12.
Nailing
Flanges
Figure 11 - Location of Nailing Flanges
BUILT-IN FIREPLACE
INSTALLATION
| Actual |
| Framing | |
|
|
|
| |
Height | 32 3/8" |
| 33" | |
Front Width | 34 5/ | 16 | " | 35 1/ " |
|
|
| 2 | |
Depth | 16 11/16" | 17 3/4" |
1.Frame in rough opening. Use dimen- sions shown in Figure 13 for the rough opening.
If installing in a corner, use dimen- sions shown in Figure 14 for the rough opening. The height is 33" which is the same as the wall opening above.
2.If using blower, install and properly ground GA3555,
3.Install gas piping to fireplace location. This installation includes an approved flexible gas line (if allowed by local codes) after the equipment shutoff valve. The flexible gas line must be the last item installed on the gas pip- ing. See Installing Gas Piping to Fire- place Location, page 10.
4.Carefully set fireplace in front of rough opening with back of fireplace inside wall opening.
5.Attach flexible gas line to gas supply. See Connecting Fireplace to Gas Sup- ply, page 11.
6.Carefully insert fireplace into rough opening.
7.Attach fireplace to wall studs using nails or wood screws through holes in nailing flange (see Figure 15).
8.Check all gas connections for leaks. See Checking Gas Connections, page 12.
9.Plug electrical cord into electrical out- let installed in step 2.
10.Install brass trim after final finishing and/or painting of wall (see Figure 7, page 8).
17 3/4"
33"
35 1/2"
Figure 13 - Rough Opening for Installing in Wall
39 3/8"
27 7/8"
35 1/2" 55 5/8"
Figure 14 - Rough Opening for Installing in Corner
Nails or
Wood
Screws
Nailing Flanges
Figure 15 - Attaching Fireplace to Wall Studs
Figure 12 - Inserting Fireplace Into Cabinet Mantel
Continued
104636 | 9 |