INSTALLATION

Continued

OPTIONAL Wireless hand-held REMOTE CONTROL ACCESSORies Remote-Ready Models Only (HRC100 Series & HRC200 Series)

Installing Receiver

1. Disconnect wires from the control valve (see Figure 26) .

2. Locate the battery clip mounted on the back of the receiver (see Figure 27).

3. Slide 9-volt battery (not included) through the clip.

4. Attach the terminal wires to the battery (see Figure 27).

5. Connect wires from remote receiver to control valve as shown in Figure 28.

6. Install remote receiver unit onto remote/ blower bracket using screws provided (see Figure 28).

Figure 26 - Disconnecting Wires From

Control Valve

Receiver

9-Volt

Terminal

Battery

Wires

 

Battery Clip

Figure 27 - Attaching Battery to Receiver

White Wire to

TH Terminal on

Control Valve

Remote

Receiver

Red Wire to

TPTH Terminal on

Control Valve

Figure 28 - Installing Remote Receiver

Installing 9-Volt Battery in Hand-Held

Remote Control Unit

1. Remove battery cover on back of remote control unit.

2. Attach terminal wires to the battery (not in- cluded). Place battery into the battery housing.

3. Replace battery cover onto remote control unit.

Battery

Remote Control Unit

Cover

Terminal

Wires

Battery

Housing

9-Volt Battery

Figure 29 - Installing Battery in Hand-

Held Remote Control Unit

optional Wall Mounted Thermostat - GWMT1 (Remote-Ready Models Only)

WARNING: Read and fol- low installation instructions. Installation should be done by a qualified installer familiar with low-voltage wiring procedures.

WARNING: Do not connect this thermostat to any electrical source! Electrical shock and/or fire hazard will occur.

1.Remove jumper wire from control valve (see Figure 26).

2.Connect one terminal of 25 ft. wire to the “TH” terminal on the control valve. Connect the other terminal to the “THTP” terminal on the control valve. See Figure 30, page 20.

3.Route the 25 ft. wire to a convenient location to mount your thermostat (no outside wall).

IMPORTANT: The wire may be shortened but must not be lengthened.

The thermostat should be mounted 54" above the floor in a location where there is good air circulation. Avoid heat sources such as lamps, direct sunlight, fireplace or heat and air conditioning ducts.

116526-01B

www.desatech.com

19