OWNER’S MANUAL
INSTALLATION
NOTICE: This heater is intended for use as supplemental heat. Use this heater along with your pri- mary heating system. Do not in- stall this heater as your primary heat source. If you have a central heating system, you may run system’s circulating blower while using heater. This will help circu- late the heat throughout the house. In the event of a power outage, you can use this heater as your primary heat source.
 WARNING: A qualified ser- vice person must install heater. Follow all local codes.
NOTICE: State or local codes may only allow operation of this appli- ance in a vented configuration. Check your state or local codes.
 WARNING: Make sure the se- lector switch is in the OFF posi- tion before installing heater.
 WARNING: Before installing in a solid fuel burning fireplace, the chimney flue and firebox must be cleaned of soot, creosote, ashes and loose paint by a quali- fied chimney cleaner. Creosote will ignite if highly heated. A dirty chimney may create and distrib- ute soot within the house. Inspect chimney flue for damage. If dam- aged, operate heater with flue damper closed.
 WARNING: Seal any fresh air vents or ash 
 WARNING: Never install the heater
•in a bedroom or bathroom un- less installed as vented appli- ance, see page 10
•in a recreational vehicle
•where curtains, furniture, cloth- ing, or other flammable objects are less than 42 inches from the front, top, or sides of the heater
•in high traffic areas
•in windy or drafty areas
 CAUTION: This heater cre- ates warm air currents. These currents move heat to wall sur- faces next to heater. Installing heater next to vinyl or cloth wall coverings or operating heater where impurities (such as to- bacco smoke, aromatic candles, cleaning fluids, oil or kerosene lamps, etc.) in the air exist, may discolor walls.
IMPORTANT: 
CHECK GAS TYPE
Use only propane/LP gas. If your gas sup- ply is not propane/LP gas, do not install heater. Call dealer where you bought heater for proper type heater.
INSTALLATION AND CLEARANCES (Vent-Free  Operation Only)
 WARNING: Maintain the mini- mum clearances. If you can, pro- vide greater clearances from floor, ceiling, and adjoining wall.
MINIMUM FIREPLACE CLEARANCE
TO COMBUSTIBLE MATERIALS
Log Size  | Side Wall  | Ceiling  | Floor*  | 
18", 24", 30”  | 16"  | 42"  | 5"  | 
  | 
  | 
  | 
  | 
*See Floor Clearances, page 9.
LOG SIZING REQUIREMENTS
  | Minimum Firebox Size  | |||
Log | 
  | 
  | 
  | 
  | 
  | 
  | Front | Rear* | |
Size | Height | Depth | Width | Width  | 
  | 
  | 
  | 
  | 
  | 
18"  | 17"  | 14"  | 20"  | 14"  | 
24"  | 17"  | 14"  | 26"  | 18"  | 
30"  | 17"  | 14"  | 32"  | 22"  | 
  | 
  | 
  | 
  | 
  | 
*Measured at 14” depth
Carefully follow the instructions below. This will ensure safe installation into a masonry, 
Minimum Clearances For Side
Combustible Material, Side Wall,
and Ceiling
A.Clearances from the side of the fire- place cabinet to any combustible ma- terial and wall should follow the dia- gram in Figure 4.
Example: The face of a mantel, book- shelf, etc. is made of combustible ma- terial and protrudes 3 1/2" from the wall. This combustible material must be 4" from the side of the fireplace opening (see Figure 4).
Note: When installing your gas logs into a manufactured firebox, follow firebox manufacturer’s instructions for minimum clearances to combustible materials.
B.Clearances from the top of the fireplace opening to the ceiling should not be less than 42 inches.
  | Example  | 
  | 
  | 
  | 
  | 
  | 
  | 121/4  | 
  | ||
  | 
  | 
  | 
  | 
  | 
  | 
  | 101/2  | 
  | |||
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 8 3/4  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 7  | INCHES  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 51/4  | |
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 31/2  | |
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 13/4  | |
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | |
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 7/8  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 7/16  | 
  | 
FIREBOX  | .5  | 1  | 2  | 4  | 6  | 8  | 10  | 12  | 14  | 16 *  | 
  | 
  | 
  | 
  | 
  | INCHES  | 
  | 
  | 
  | 
  | 
  | ||
*Minimum 16 inches from Side Wall
Figure 4 - Minimum Clearance for Combustible to Wall
Continued
105073  | 7  |