Desa VGC30NR/PR Operating Heater, Inspecting Burners, Wiring Diagram, Cleaning and Maintenance

Models: VGC24NR/PR VGC30NR/PR

1 36
Download 36 pages 60.66 Kb
Page 23
Image 23
Inspecting Burners

Operating Heater

Continued

2.The receiver continuously receives signals from the hand-held remote to control the room temperature. If the hand-held remote is misplaced, obstructed or for any reason cannot transmit to the receiver, the receiver will shut off the fireplace after 8 minutes.

Key Pad Lock Feature

This feature allows the user to lock/unlock the keypad on the hand-held remote in the MANU or AUTO mode to prevent inadvertent operation (i.e. children operating the hand-held remote control, etc.). The keypad is locked in either on or off. Press the POWER and LOCK buttons together to turn the unit on or off.

Inspecting Burners

Check pilot flame pattern and burner flame pat- terns often.

PILOT FLAME PATTERN

Figure 35 shows a correct pilot flame pattern. Figure 36 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touching the thermocouple. This will cause the thermocouple to cool. When the thermocouple cools, the heater will shut down.

If pilot flame pattern is incorrect, as shown in Figure 36

turn heater off (see To Turn Off Gas to Appli- ance, page 21

see Troubleshooting, page 25

Note: The pilot flame on natural gas units will have a slight curve, but flame should be blue and have no yellow or orange color.

Pilot Burner

Thermocouple

Figure 35 - Correct Pilot Flame Pattern

Pilot Burner

Thermocouple

Figure 36 - Incorrect Pilot Flame Pattern

Wiring Diagram

To

Thermopile

To AUTO/OFF/ON

Switch or Remote

Receiver

Cleaning and

Maintenance

PILOT FLAME PATTERN WARNING: Turn off heater and let cool before cleaning.

Wiring Diagram CAUTION: You must keep control areas, burners and circulating air passageways of heater clean. Inspect these areas of heater before each use. Have heater inspected yearly by a qualified service person. Heater may need more frequent cleaning due to excessive lint from carpeting, pet hair, bedding material, etc.

Cleaning and WARNING: Failure to keep the primary air opening(s) of the burner(s) clean may result in sooting and property damage.

119162-01B

www.desatech.com

23

Page 23
Image 23
Desa VGC30NR/PR Operating Heater, Inspecting Burners, Wiring Diagram, Cleaning and Maintenance, Pilot Flame Pattern