Desa VGC30NR/PR Continued, Observed Problem, Possible Cause, Remedy, and Maintenance, page

Models: VGC24NR/PR VGC30NR/PR

1 36
Download 36 pages 60.66 Kb
Page 27
Image 27
Manual background

Troubleshooting

Continued

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

 

 

 

 

 

 

Slight smoke or odor during

1.

Residues from manufacturing

1.

Problem will stop after a few

initial operation

 

processes and logs curing

 

hours of operation

 

 

 

 

 

 

Heater produces a whistling

1.

Turning control knob to HI

1.

Turn control knob to LO

noise when burners are lit

 

position when burners are

 

position and let warm up for

 

2.

cold

2.

a minute

 

Air in gas line

Operate burners until air is

 

 

 

 

removed from line. Have gas

 

 

 

 

line checked by local natural

 

3.

Air passageways on heater

3.

or propane/LP gas company

 

Observe minimum installa-

 

 

blocked

 

tion clearances (see pages 9

 

4.

Dirty or partially clogged

4.

through 11)

 

Clean burners (see Cleaning

 

 

burner orifice(s)

 

and Maintenance, page 23)

 

 

 

 

or replace burner orifice(s)

 

White powder residue forming

1.

When heated, vapors from

1.

Turn heater off when using

within burner box or on adjacent

 

furniture polish, wax, carpet

 

furniture polish, wax, carpet

walls or furniture

 

cleaners, etc. may turn into

 

cleaners or similar products

 

 

white powder residue

 

 

 

Moisture/condensation noticed

1.

Not enough combustion/ven-

1.

Refer to Air for Combustion

on windows

 

tilation air

 

and Ventilation requirements

 

 

 

 

(page 6)

 

Remote does not function (Re-

1.

Battery is not installed. Bat-

1.

Replace 9-volt batteries in re-

mote-Ready Models Only)

 

tery power is low

 

ceiver and hand-held remote

 

 

 

 

 

 

Heater produces a clicking/tick-

1.

Metal expanding while heating

1.

This is normal with most heat-

ing noise just after burners are

 

or contracting while cooling

 

ers. If noise is excessive, contact

lit or shut off

 

 

 

qualified service person

119162-01B

www.desatech.com

27

Page 27
Image 27
Desa VGC30NR/PR, VGC24NR/PR installation manual Continued, Observed Problem, Possible Cause, Remedy, and Maintenance, page