WIRING DIAGRAM
|
| Black | ||
On | Receiver | |||
|
| |||
Off | Red | |||
Remote |
| |||
|
|
|
REPLACEMENT PARTS
Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty.
Thermopile
TPTH TH
Gas Control
TPTH TP
Red
White
PARTS UNDER WARRANTY
Contact authorized dealers of this product. If they canʼt supply original replacement part(s), call DESA Heating Productsʼ Technical Service Department at
SERVICE HINTS
When Gas Pressure Is Too Low
•pilot will not stay lit
•burners will have delayed ignition
•heater will not produce specified heat
•propane/LP gas supply may be low
You may feel your gas pressure is too low. If so, contact your local propane/LP gas supplier.
TECHNICAL SERVICE
You may have further questions about installation, operation, or troubleshooting. If so, contact DESA Heating ProductsʼTechnical Service Department at
You can also visit DESA Heating Productsʼtechni- cal service web site at www.desatech.com.
When calling DESA Heating Products, have ready
•your name
•your address
•model and serial numbers of your heater
•how heater was malfunctioning
•type of gas used (propane/LP or natural gas)
•purchase date
Usually, we will ask you to return the part to the factory.
PARTS NOT UNDER WARRANTY
Contact authorized dealers of this product. If they canʼt supply original replacement part(s) call DESA Heating Products at
When calling DESA Heating Products, have ready
•model number of your heater
•the replacement part number
SPECIFICATIONS
| VGL18PRA | VGL18NRA |
| VGL24PRA | VGL24NRA |
| VGL30PRA | VGL30NRA |
Btu (Variable) | 21,000/30,000 | 21,000/30,000 |
Type Gas | Propane/LP | Natural Gas |
Ignition | Electronic | Electronic |
Manifold Pressure | 8.0" W.C. | 3.5" W.C. |
Inlet Gas Pressure (in. of water) |
| |
Maximum | 14" | 10.5" |
Minimum* | 11" | 5" |
* For the purpose of input adjustment
28 | www.desatech.com |