PARTS UNDER WARRANTY

WIRING DIAGRAM

 

 

Black

On

Receiver

 

 

Off

Red

Remote

 

 

 

 

REPLACEMENT PARTS

Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty.

Thermopile

TPTH TH

Gas Control

TPTH TP

Red

White

PARTS UNDER WARRANTY

Contact authorized dealers of this product. If they canʼt supply original replacement part(s), call DESA Heating Productsʼ Technical Service Department at 1-866-672-6040.

SERVICE HINTS

When Gas Pressure Is Too Low

pilot will not stay lit

burners will have delayed ignition

heater will not produce specified heat

propane/LP gas supply may be low

You may feel your gas pressure is too low. If so, contact your local propane/LP gas supplier.

TECHNICAL SERVICE

You may have further questions about installation, operation, or troubleshooting. If so, contact DESA Heating ProductsʼTechnical Service Department at 1-866-672-6040. When calling, please have your model and serial numbers of your heater ready.

You can also visit DESA Heating Productsʼtechni- cal service web site at www.desatech.com.

When calling DESA Heating Products, have ready

your name

your address

model and serial numbers of your heater

how heater was malfunctioning

type of gas used (propane/LP or natural gas)

purchase date

Usually, we will ask you to return the part to the factory.

PARTS NOT UNDER WARRANTY

Contact authorized dealers of this product. If they canʼt supply original replacement part(s) call DESA Heating Products at 1-866-672-6040 for referral information.

When calling DESA Heating Products, have ready

model number of your heater

the replacement part number

SPECIFICATIONS

 

VGL18PRA

VGL18NRA

 

VGL24PRA

VGL24NRA

 

VGL30PRA

VGL30NRA

Btu (Variable)

21,000/30,000

21,000/30,000

Type Gas

Propane/LP

Natural Gas

Ignition

Electronic

Electronic

Manifold Pressure

8.0" W.C.

3.5" W.C.

Inlet Gas Pressure (in. of water)

 

Maximum

14"

10.5"

Minimum*

11"

5"

* For the purpose of input adjustment