DESA INTERNATIONAL

UNVENTED PROPANE/LP GAS FIREPLACE INSERT

INSTALLATION

Continued

2.Pressurize supply piping system by ei- ther using compressed air or opening propane/LP supply tank valve.

3.Check all joints from propane/LP sup- ply to equipment shutoff valve (see Fig- ure 22). Apply mixture of liquid soap and water to gas joints. Bubbles form- ing show a leak.

4.Correct all leaks at once.

Pressure Testing Fireplace Insert Gas Connections

1.

Open equipment shutoff valve (see

 

Figure 21, page 11).

2.

Open propane/LP supply tank valve.

3.

Make sure control knob of fireplace

 

insert is in the OFF position.

4.

Check all joints from equipment shutoff

 

valve to thermostat gas valve (see Fig-

 

ure 22). Apply mixture of liquid soap

 

and water to gas joints. Bubbles form-

 

ing show a leak.

5.

Correct all leaks at once.

6.

Light fireplace insert (see Operating

 

Fireplace Insert, pages 14 through 16).

 

Check all other internal joints for leaks.

7.

Turn off fireplace insert (see To Turn

 

Off Gas to Appliance, page 15).

INSTALLING LOGS

CAUTION: Do not remove the warning and instruction labels attached to the heater base as- sembly. These markings contain important warranty information.

WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury.

WARNING: After installation and periodically thereafter, check to ensure that no flame comes in contact with any log. With the heater set to High, check to see if flames contact any log. If so, re- position logs according to the log installation instructions in this manual. Flames contacting logs will create soot.

It is very important to install the logs exactly as instructed. Do not modify logs. Only use logs supplied with heater.

1.Place one-piece log set on grate to fit as illustrated in Figure 23. Make sure middle section at bottom of log set is seated into "U"-shaped cutout in cen- ter of chassis (see Figure 24).

IMPORTANT: Make sure log does not cover any burner ports.

One Piece

Log Set

Middle

Section at

Bottom of

Log Set

Burner

"U"-shaped

ChassisCutout in Chassis

Figure 23 - Installing One Piece Log Set

Burner Ports

One Piece Log Set

Equipment Shutoff

Propane/LP

Supply

Valve

Tank

Manual Gas Valve

 

Figure 24 - Installing One Piece Log Set (Top View)

Figure 22 - Checking Gas Joints

For more information, visit www.desatech.com

12

105648

Page 12
Image 12