DESA INTERNATIONAL
UNVENTED PROPANE/LP GAS FIREPLACE INSERT
OPERATING FIREPLACE INSERT
Continued
GHRCTA Series Operation:
2b. Press theAUTO/ON/OFF button on the
•In the ON mode, the burners will ignite. The heater is in manual mode when ON is lit.
•In the AUTO mode, the thermostat in the
IMPORTANT: This remote control has been specially engineered to take an air temperature sample ev- ery 5.5 minutes in the auto mode. It will not respond immediately to the temperature setting being turned up or down.
IMPORTANT: The
3.To turn the burner off, press the AUTO/ON/OFF button until OFF lights. The pilot will remain lit.
IMPORTANT: To turn the pilot off, manually turn the control knob on the heater to the OFF position.
OPTIONAL BLOWER
OPERATION
Locate the blower switch by opening lower louver on fireplace insert. Blower switch is located at lower left inside louver door.
Note: Your gas logs and thermostat blower will not turn on and off at the same time. The fireplace insert may run for several minutes before the blower turns on. After the heater modulates to the pilot position, the blower will con- tinue to run. The blower will shut off after the firebox temperature decreases.
Note: It is safe to operate fireplace insert with blower turned off. However, the blower helps distribute heated air from the fireplace insert.
INSPECTING
BURNERS
Check pilot flame pattern and burner flame patterns often.
PILOT FLAME PATTERN
Figure 36 shows a correct pilot flame pat- tern. Figure 37 shows an incorrect pilot flame pattern. The incorrect pilot flame is not properly heating the thermocouple. When the thermocouple cools, the heater will shut down.
If pilot flame pattern is incorrect, as shown in Figure 37
•turn heater off (see To Turn Off Gas to Appliance, page 15)
•see Troubleshooting, pages 17 through 19
Pilot Burner
Thermocouple
Figure 36 - Correct Pilot Flame Pattern
Pilot Burner
Thermocouple
Figure 37 - Incorrect Pilot Flame Pattern
BURNER PRIMARY AIR HOLES
Air is drawn into the burner through the holes in the fitting at the burner entrance. These holes may become blocked with dust or lint. Periodically inspect these holes for any blockage and clean if needed. Blocked air holes will create soot.
MAIN BURNER
Periodically inspect all burner flame holes with the heater running. All slotted burner flame holes should be open with yellow flame present. All round burner flame holes should be open with a small blue flame present. Some burner flame holes may be- come blocked by debris or rust, with no flame present. If so, turn off heater and let cool. Either remove blockage or replace burner. Blocked burner flame holes will create soot.
BURNER FLAME PATTERN
Figure 38 shows a correct burner flame pat- tern. Figure 39 shows an incorrect burner flame pattern. If burner flame pattern is incorrect,
•turn heater off (see To Turn Off Gas to Appliance, page 15)
•see Troubleshooting, pages 17 through 19
Approx.
Top of Logs
Figure 38 - Correct Flame Pattern with Control Knob Set to High Flame.
More Than 8"
Above Top of Logs
Figure 39 - Incorrect Flame Pattern with Control Knob Set to High Flame
For more information, visit www.desatech.com | 16 | 105648 |