Desa VM42P installation manual Gas leak. See Warning

Models: VM42P

1 32
Download 32 pages 38.65 Kb
Page 25
Image 25

TROUBLESHOOTING

Continued

WARNING: If you smell gas

Shut off gas supply.

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

IMPORTANT: Operating fireplace where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors.

OBSERVED PROBLEM POSSIBLE CAUSE

REMEDY

Fireplace produces unwanted 1. Fireplace burning vapors

odorsfrom paint, hair spray, glues, etc. (See IMPORTANT state- ment above)

2. For propane/LP gas, low fuel supply

3. Gas leak. See Warning statement at top of page

1.Ventilate room. Stop using odor causing products while fireplace is running

2.Contact local propane/LP sup- plier

3.Locate and correct all leaks (see Gas Line Hook-Up, page 13)

Gas odor even when control knob

1. Gas leak. See Warning

1.

Locate and correct all leaks (see

is in OFF position

 

statement at top of page

 

Gas Line Hook-Up, page 13)

 

2.

Control valve defective

2.

Replace control valve

 

 

 

 

Gas odor during combustion

1. Foreign matter between con-

1.

Take apart gas tubing and

 

 

trol valve and burner

 

remove foreign matter

 

2.

Gas leak. See Warning

2.

Locate and correct all leaks (see

 

 

statement at top of page

 

Gas Line Hook-Up, page 13)

 

 

 

 

Dark residue on logs or inside

1. Improper log placement

1.

Properly locate logs

of fireplace

2. Air holes at burner inlet

2.

Clean out air holes at burner

 

 

blocked

 

inlets. Periodically repeat as

 

3.

Burner flame holes blocked

 

needed

 

3.

Remove blockage or replace

 

 

 

 

burner

 

4.

Improper venting or ex-

4.

Have the vent system inspect-

 

 

cessive blockage

 

ed, including the termination

 

 

 

 

cap. Remove any restrictions

 

 

 

 

or obstruction

 

5.

Excessive amounts of embers

5.

Clear excess embers until a

 

 

and pan material

 

minimum gap of 1/2" remains

 

 

 

 

under the grate

108795-01N