Desa VM42P Optional Wireless HAND-HELD Remote Control Installation, Installing Receiver

Models: VM42P

1 32
Download 32 pages 38.65 Kb
Page 12
Image 12

INSTALLATION

Continued

OPTIONAL WIRELESS HAND-HELD REMOTE CONTROL INSTALLATION

Note: If using optional wireless hand-held remote control, the wall switch is no longer operational.

Installing Receiver

1.Remove the front refractory access panel by lifting up and angling out of the firebox opening (see Figure 13, page 11) to expose controls.

2.Disconnect wall switch wires from TH and TH/TP terminals on control valve (see Figure 14).

3.Install remote receiver unit onto mounting bracket using the two plastic mounting clips (see Figure 15).

4.Connect wires to control circuit. Connect white wire to terminal marked TH/TP on control valve. Connect red wire to male blade connector provided at open end of safety cir- cuit wiring (see Wiring Diagram, page 22).

5.Locate the battery clip mounted on the back of the receiver (see Figure 16).

6.Slide 9-volt battery (not included) through the clip. Note: Only use alkaline battery.

7.Attach the terminal wires to the battery (see Figure 16).

8.Replace refractory brick access panel.

Receiver

Plastic

Mounting

Clips

Mounting Bracket

Figure 15 - Installing Remote Receiver (Shown from Rear of Mounting Bracket)

9-Volt Battery

Battery

Clip

Terminal

Wires

Receiver

Figure 16 - Installing Battery in Receiver

To Safety Circuit

Route Millivolt

Wall Switch

Wires (Supplied)

(Supplied)

 

 

Through Gas Line

 

 

Conduit Sleeve

 

 

To Thermopile

 

 

 

 

ON

IN

LO

T

 

 

TH

P

 

I

 

 

 

 

 

FFO

 

 

 

TP

 

 

 

THTP

 

IN

 

OUT

Note: If any of the original wire as supplied must be replaced, use 18 AWG TYPE CL2 (UL) 105 C (25 ft. length MAXIMUM) or equivalent.

Figure 14 - Wall Switch Wiring Diagram

(Back View

12

www.desatech.com

108795-01N

Page 12
Image 12
Desa VM42P installation manual Optional Wireless HAND-HELD Remote Control Installation, Installing Receiver