TROUBLESHOOTING

Continued

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

Pilot goes out when wall switch

1. Millivolt output on thermo-

1. Replace thermopile

is ON

pile too high

 

 

 

 

Spark ignitor will not light pilot

1. Defective ignitor (no spark at

1. Check for spark at the elec-

after repeated triggering of red

electrode)

trode and pilot; if no spark

button

 

and electrode wire is properly

 

 

connected, replace ignitor

 

2. Defective pilot or misaligned

2. Using a match, light pilot. If

 

electrode at pilot (spark at

pilot lights, turn off pilot and

 

electrode)

trigger the red button again.

 

 

If pilot lights, an improper

 

 

gas/air mixture caused the

 

 

improper lighting and a longer

 

 

purge period is recommended.

 

 

If pilot will not light, check

 

 

gap at electrode and pilot. Gap

 

 

should be 1/8" to have a strong

 

 

spark. If okay, replace pilot

 

3. No gas or low gas pressure

3. A) Check remote shut off

 

 

valves from fireplace. Usually

 

 

there is a valve near the fire-

 

 

place and sometimes there is a

 

 

valve near the main. There can

 

 

be more than one (1) valve be-

 

 

tween the fireplace and main

 

 

B) Low pressure can be caused

 

 

by a variety of situations such

 

 

as bent line, or gas supplier

 

4. If using propane/LP gas, no

4. Check propane/LP supply

 

propane/LP gas in tank

and contact local propane/LP

 

 

supplier

 

 

 

Fireplace produces a clicking/

1. Metal expanding while heating

1. This is common with most

ticking noise just after burner is

or contracting while cooling

fireplaces. If noise is exces-

lit or shut off

 

sive, contact qualified service

 

 

person