OPERATING FIREPLACE
Continued
TO TURN OFF GAS
TO APPLIANCE
1.Turn off the wall switch.
2.Turn off all electric power to the appliance if service is to be performed.
3.Fully open glass doors if installed.
4.Remove front hearth brick and control access panel.
5.Turn gas control knob clockwise to “OFF”. Do not force.
6.Replace front refractory brick access panel.
7.Fully close glass doors if installed.
Pilot
Burner
Thermopile
Ignitor
Figure 40 - Pilot
OPTIONAL HAND-HELD
REMOTE OPERATION
Note: The receiver and
1.After lighting, let pilot flame burn for about one minute. Turn control knob to ON position. Slide the selector switch to the REMOTE position. Note: The burner may light if
IMPORTANT: Do not leave the selector switch in the REMOTE or ON position when the pilot is not lit. This will drain the battery.
2.Press the control button on the
3.To Lock press both buttons on remote control until light stops flashing. Remote is now locked. If the fire is on it will be turned off automatically. In the locked state, the light will not light up when any button is pressed.
4.To Unlock press both buttons together on remote control until light stops flashing. The remote is now unlocked.
Indicator
Light
Control
Button
Figure 41 - On/Off Hand-Held Remote Control Unit HRC100
INSPECTING BURNERS
Check pilot flame pattern and burner flame pat- terns often.
PILOT ASSEMBLY
The pilot assembly is factory preset for the proper flame height. Alterations may have occurred dur- ing shipping and handling. The pilot is located on the back right hand side of the burner.
The height of the thermopile must be 3/8" to 1/2" above the pilot flame. The flame from the pilot burner must extend beyond the thermopile.
If your pilot assembly does not meet these re- quirements:
•Turn the adjustment screw marked pilot clockwise to decrease or counterclockwise to increase the flame to proper size (see Figure 39, page 19). Do not remove the adjustment screw.
•see Troubleshooting, page 19
20 | www.desatech.com |