OPERATINGGWMT1 WALL

FIREPLACEMOUNTEDTHERMOSTAT(OPTIONAL)OPERATING BLOWER ® VMH26PR

COMPACT CLASSIC HEARTH FIREPLACE

OPERATINGGWMT1 WALL

FIREPLACE

MOUNTED

THERMOSTAT

Continued

(OPTIONAL)

 

OPERATING BLOWER

This blower has three settings: ON, OFF, and AUTO. In the ON position, the blower will operate constantly. In the OFF posi-

IMPORTANT: The hand-held remote control unit must be near the heater. Do not keep the hand-held remote control unit too close to the heater. The thermostat on the hand-held re- mote control unit will heat up too quickly and turn the heater off.

3.Use the STATUS button on the hand- held remote control unit to see the operation mode being used and the temperature setting selected. A red light will come on beside the opera- tion mode being used when the sta- tus button is pressed.

4.To turn the burner off when operating in the manual mode, press the OFF button. If operating in the auto mode, press the MAN button, then press the OFF button. The pilot will remain lit. IMPORTANT: To turn the pilot off, manually turn the control knob on the heater to the OFF position.

Make sure the heater switch is on AUTO and set the temperature adjustment on wall thermostat to the desired setting. The thermostat has been electronically calibrated at the factory and requires no adjustment or leveling.

Upon installation, the thermostat must be allowed to stabilize at room tempera- ture for a minimum of 30 minutes for proper operation. See installation instruc- tions on pages 16 and 17 of this manual.

GWMS2 WALL

MOUNTED SWITCH

(OPTIONAL)

Make sure the heater switch is on AUTO. This wall switch works just like the con- ventional light switch. Flip the switch up for on and down for off.

Note: Make sure that this switch is not in a position to be mistaken for a light switch. This may result in the heater being inad- vertently turned on without the proper precautions being taken. See installation instructions on page 17 of this manual.

tion, the blower will not operate. In the AUTO position, the blower will start when the thermostat senses a sufficient increase in firebox temperature.

Note: Your fireplace and thermostat blower will not turn on and off at the same time. The fireplace may run for several minutes before the blower turns on. After the heater modulates to the pilot position, the blower will continue to run. The blower will shut off after the firebox temperature decreases.

Note: It is safe to operate fireplace with blower turned off. However, the blower helps distribute heated air from the fireplace.

Auto/Off/On Switch

Shows Temp.

 

 

Increases

Setting

 

HI

Room

 

 

Temp.

Allows Burner

 

 

 

 

 

to be Turned

 

TEMP

Decreases

On and Off

 

 

Room

with the Hand-

 

 

Temp.

Held Remote

 

 

Turns

Unit.

MAN

LO ON

 

 

The Log

 

 

Burner On

AUTO

OFF

and Off

Heater will

 

 

 

 

 

Automatically

 

STATUS

Shows

Cycle between

 

 

 

Current

Pilot and the

 

 

 

 

Operation

Heat Setting

 

 

 

 

Mode

that has been

 

 

 

 

 

Selected.

 

 

 

Figure 39 - Auto/Off/On Switch

Figure 38 - Thermostat Hand-Held Remote Control Unit

Selections (GHRCT only)