1.Remove screws.

2.Disconnect switch wires from the con- trol valve.

3.Remove switch plate (see Figure 28). Discard switch plate after removing. Save the screws.

4.Locate the battery clip mounted on the back of the receiver (see Figure 29).

5.Slide 9-volt battery (not included) through the clip.

6.Attach the terminal wires to the battery (see Figure 29).

7.Connect wires as shown in Figure 30.

8.Install remote receiver unit onto gas heater base using the two screws re- moved in step one (see Figure 30).

Screw Manual background

Switch Plate

Manual backgroundRed Wire

Black Wire

Heater Base

Figure 28 - Switch Plate and Wiring Harness

Receiver

Terminal

Wires

Battery Clip

9-Volt Battery

Figure 29 - Attaching Battery to Receiver

 

Remote

 

Receiver

Black Wire

Red Wire

 

Wire Harness*

 

Wires from

Valve

Black Wire

Red Wire

Figure 30 - Installing Remote Receiver

*Wire harness provided in the fireplace hardware pack.

Installing 9-Volt Battery in Hand- Held Remote Control Unit

1.Remove battery cover on back of re- mote control unit.

2.Attach terminal wires to the battery (not included). Place battery into the battery housing.

3.Replace battery cover onto remote con- trol unit.

Terminal

Battery

Remote

Control Unit

Cover

Wires

 

 

 

9-Volt

 

 

Battery

 

 

 

 

Battery

 

 

Housing

Figure 31 - Installing Battery in Hand- Held Remote Control Unit

OPTIONAL WALL MOUNTED THERMOSTAT - GWMT1

Manual background WARNING: Read and follow installation instructions. Instal- lation should be done by a quali- fied installer familiar with low- voltage wiring procedures.

Manual background WARNING: Do not connect this thermostat to any electrical source! Electrical shock and/or fire hazard will occur.

1.Connect one terminal of 25 ft. wire to bottom contact of switch (see Figure 32, page 17).

2.Connect remaining wire terminal to the “TH” terminal on the control valve. Make sure that wire terminals are in the positions on your unit as pictured in Figure 32 on page 17. If wires are not “crossed” the thermostat will not work.

3.Route the 25 ft. wire to a convenient location to mount your thermostat (no outside wall). IMPORTANT: The wire may be shortened but must not be lengthened.

The thermostat should be mounted 54" above the floor in a location where there is good air circulation.Avoid heat sources such as lamps, direct sunlight, fireplace, or heat and air conditioning ducts.

4.Gently remove the cover of the ther- mostat from the base. Grasp the sides of the cover firmly and pull to separate from the base.

5.Feed the electrical wires through the rectangular slots on each side of the base (see Figure 33, page 17).

Manual background WARNING: Do not connect the thermostat to a power source. Electrical shock and/or a fire haz- ard will occur.