OBSERVED PROBLEM | POSSIBLE CAUSE | REMEDY | ||
When ignitor button is pressed in, there is no | 1. | Ignitor electrode positioned wrong | 1. | Replace pilot assembly |
spark at ODS/pilot | 2. | Ignitor electrode broken | 2. | Replace pilot assembly |
| 3. | Ignitor electrode not connected to igni- | 3. | Reconnect ignitor cable |
|
| tor cable |
|
|
| 4. | Ignitor cable pinched or wet | 4. | Free ignitor cable if pinched by any |
|
|
|
| metal or tubing. Keep ignitor cable dry |
| 5. | Broken ignitor cable | 5. | Replace ignitor cable |
| 6. | Bad piezo ignitor | 6. | Replace piezo |
| 7. | Piezo ignitor nut is loose | 7. | Tighten nut holding piezo ignitor. Nut |
|
|
|
| is located inside heater cabinet at top |
|
|
|
|
|
When ignitor button is pressed in, there is a | 1. | Gas supply turned off or equipment | 1. | Turn on gas supply or open equipment |
spark at ODS/Pilot but no ignition |
| shutoff valve closed |
| shutoff valve |
| 2. | Control knob not fully pressed in while | 2. | Turn to PILOT/IGN position. Fully press |
|
| pressing ignitor button |
| in control knob while pressing ignitor |
|
| models only) |
| button |
|
| Thermostat control knob not fully |
| Fully press in thermostat control knob |
|
| pressed in while pressing ignitor button |
| while pressing ignitor button (thermo- |
|
| (thermostat models only) |
| stat models only) |
| 3. | Air in gas lines when installed | 3. | Continue holding down control knob. Re- |
|
|
|
| peat igniting operation until air is removed |
| 4. | Depleted gas supply (propane/LP gas) | 4. | Contact local propane/LP gas company |
| 5. | ODS/pilot is clogged | 5. | Clean ODS/pilot (see Cleaning and |
|
|
|
| Maintenance, page 17) or replace ODS/ |
|
|
|
| pilot assembly |
| 6. | Gas regulator setting is not correct | 6. | Replace gas regulator |
| 7. | Thermostat control knob is not in pilot | 7. | Turn thermostat control knob to pilot |
|
| position (thermostat models only) |
| position |