1.STOP! Read the safety information, column 2 page 14.

OPERATING HEATER (THERMOSTAT MODELS)

Lighting Instructions

15

OPERATING HEATER

Continued

LIGHTING

INSTRUCTIONS

1.STOP! Read the safety information, column 2 page 14.

2.Make sure equipment shutoff valve is fully open.

3. Turn thermostat control knob clockwise ClockwiseManual background to the OFF position (see Figure 22 or 23 for your model).

4.Wait five minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information, column 2 page 14. If you don’t smell gas, go to the next step.

5.Turn thermostat control knob counterclockwise Manual backgroundC-clockwiseto the PILOT position. Press in thermostat control knob for 5 seconds (see Figure 22 or 23 for your model).

Note: You may be running this heater for the first time after hooking up to gas supply. If so, you may need to press in thermostat control knob for 30 seconds or more. This will allow air to bleed from the gas system.

If thermostat control knob does not pop up when released, contact a qualified service person or gas supplier for repairs.

6.Keep thermostat control knob pressed in while pushing down and releasing the ignitor button. This will light pilot. If nec- essary, continue to press ignitor button until pilot lights.

If pilot does not light

• turn thermostat control knob clockwise ClockwiseManual background to the

OFF position

repeat steps 5 and 6

If pilot does not stay lit after several tries

refer to Troubleshooting, pages 19 through 21

contact a qualified service person or gas supplier

Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure, page 16.

7.Keep thermostat control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

Note: If pilot goes out, repeat steps 3 through 7. This heater has a safety interlock system. Wait one minute before light- ing pilot again.

8.Turn thermostat control knob counterclockwise Manual backgroundC-clockwiseto the desired heating level. For models, VP16T, VN18T, VP26T, and VN30T, the main burner should light. Set con- trol knob to any heat level between HI and LOW (see Fig- ure 25). For infrastat models, the plaque directly above the pilot should light.

Manual background CAUTION: Do not try to adjust heating levels by using the equipment shutoff valve.

Ignitor

 

 

Control

Button

PILOT

LO

Knob

 

OFF

 

 

HI

 

 

 

IGNITOR

 

 

Figure 22 - Control Knob In The OFF Position, Models VP16T, VN18T, VP26T, & VN30T

Plaque Control Knob

Ignitor Button

Thermostat

Control Knob

 

1

 

 

 

2

 

 

 

 

 

TOLIP

LO

 

 

 

 

 

FFO

 

 

 

HI

 

3

 

 

 

4

IGNITOR

 

 

 

 

 

Figure 23 - Thermostat Control Knob In The OFF Position, Models VP16IT, VN18IT, VP26IT, & VN30IT

Thermocouple

Ignitor Electrode

Pilot Burner

Figure 24 - Pilot

 

 

Control Knob

VP16T

VP26T

VN18T

VN30T

 

 

 

 

PILOT

 

 

 

F

 

 

 

 

F

 

 

 

 

O

 

 

 

IH

LO

 

 

T

ILOP

LO

 

 

OFF

 

 

 

 

HI

 

 

 

Figure 25 - Burner Patterns

For moreManual backgroundManual backgroundManual backgroundManual backgroundvisit www.Manual backgroundManual backgroundManual background.comManual backgroundManual backgroundManual backgroundManual backgroundManual background

107887-01E

Page 15
Image 15
Desa VP16, VN18, VP26 Operating Heater, Continued, Lighting Instructions, STOP! Read the safety information, column 2 page