Desa VP1600E Infrared Propane/Lp Gas Heater, Troubleshooting, Continued, Observed Problem, Remedy

Models: VP1600E VP2600E

1 24
Download 24 pages 35.24 Kb
Page 16
Image 16
Maintenance, page 13)

®

INFRARED PROPANE/LP GAS HEATER

TROUBLESHOOTING

Continued

ing Gas Connections, page 11) WARNING: If you smell gas

Shut off gas supply.

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

IMPORTANT: Operating heater where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

Heater produces unwanted odors

1.

Heater burning vapors from paint, hair

 

 

spray, glues, etc. See IMPORTANT

 

 

statement above

 

2.

Low fuel supply

 

3.

Gas leak. See Warning statement at

 

 

top of page

1.Ventilate room. Stop using odor caus- ing products while heater is running

2.Refill supply tank

3.Locate and correct all leaks (see Check- ing Gas Connections, page 11)

Heater shuts off in use (ODS operates)

1.

Not enough fresh air is available

1.

Open window and/or door for ventilation

 

2.

Low line pressure

2.

Contact local propane/LP gas company

 

3.

ODS/pilot is partially clogged

3.

Clean ODS/pilot (see Cleaning and

 

 

 

 

Maintenance, page 13)

 

 

 

 

 

Gas odor even when control knob is in

1.

Gas leak. See Warning statement at

1.

Locate and correct all leaks (see Check-

OFF position

 

top of page

 

ing Gas Connections, page 11)

 

2.

Control valve defective

2.

Replace control valve

 

 

 

 

 

Gas odor during combustion

1.

Foreign matter between control valve

1.

Take apart gas tubing and remove for-

 

 

and burner

 

eign matter

 

2.

Gas leak. See Warning statement at

2.

Locate and correct all leaks (see Check-

 

 

top of page

 

ing Gas Connections, page 11)

 

 

 

 

 

Moisture/condensation noticed on windows

1.

Not enough combustion/ventilation air

1.

Refer to Fresh Air for Combustion and

 

 

 

 

Ventilation requirements (page 4)

www.desatech.com

16

103351

Page 16
Image 16
Desa VP1600E, VP2600E Infrared Propane/Lp Gas Heater, Troubleshooting, Continued, Observed Problem, Possible Cause, Remedy