UNVENTED NATURAL GAS FIREPLACE
OPERATING
FIREPLACE
Continued
•In the AUTO mode, the thermostat in the
IMPORTANT: This remote control has been specially engineered to take an air temperature sample ev- ery minute in the auto mode. It will not respond immediately to the temperature setting being turned up or down.
IMPORTANT: The
3.To turn the burner off, press the AUTO/ON/OFF button until OFF lights. The pilot will remain lit.
IMPORTANT: To turn the pilot off, manually turn the control knob on the heater to the OFF position.
OPTIONAL BLOWER
OPERATION
WARNING: This fireplace has a
Locate the blower switch by opening lower louver on fireplace. Blower switch is lo- cated at lower left inside louver door.
The GA3700TA
Note for GA3700TA Only: If you are using GA3700TA blower, your fireplace and blower will not turn on and off at the same time. The fireplace may run for several minutes before the blower turns on. After the heater modulates to the pilot position, the blower will continue to run. The blower will shut off after the firebox temperature decreases.
Note: It is safe to operate fireplace with blowerturnedoff.However,theblowerhelps distribute heated air from the fireplace.
Follow installation instructions included with the blower accessory.
INSPECTING
BURNERS
Check pilot flame pattern and burner flame patterns often.
PILOT FLAME PATTERN
Figure 31 shows a correct pilot flame pat- tern. Figure 32 shows an incorrect pilot flame pattern. The incorrect pilot flame is not properly heating the thermocouple. When the thermocouple cools, the heater will shut down.
If pilot flame pattern is incorrect, as shown in Figure 32
•turn heater off (see To Turn Off Gas to Appliance, page 15)
•see Troubleshooting, pages 18 through 20
Pilot Burner
Thermocouple
Figure 31 - Correct Pilot Flame Pattern
Pilot Burner
Thermocouple
Shows Temperature Setting
The Log Heater will Automatically Cycle between Pilot and the Heat Setting that has been Selected
Increases Room
Temperature in AUTO
Mode
Decreases Room
Temperature in AUTO
Mode
Turns Burners On or Off and Allows You to Choose the Auto Setting
Figure 32 - Incorrect Pilot Flame Pattern
MAIN BURNER
Periodically inspect all burner flame holes with the heater running. All slotted burner flame holes should be open with yellow flame present. All round burner flame holes should be open with a small blue flame present. Some burner flame holes may be- come blocked by debris or rust, with no flame present. If so, turn off heater and let cool. Either remove blockage or replace
Figure 30 - Thermostat
burner. Blocked burner flame holes may create soot.
For more information, visit www.desatech.com | 16 | 107171 |