Desa (V)T32EN Wiring Diagram, Fireplace Installation, Continued, Wall Switch Installation

Models: (V)T32EN

1 38
Download 38 pages 61.09 Kb
Page 22
Image 22
WALL SWITCH INSTALLATION

Fireplace Installation

Continued

WALL SWITCH INSTALLATION

The installation of a wall switch allows you to activate the gas control valve and turn the fireplace on and off. The wall switch is to be connected to the incoming 120 volt regular household wir- ing that supplies the electricity to the fireplace. Refer to wiring diagram below.

optional Remote control

INSTALLATION (model WRC)

Note: If using optional wireless hand-held remote control, the wall switch must be in the ON position to be operational. The remote control then becomes the switching mechanism for fireplace op- eration.

1.Open lower louver panel of firebox.

2.The WRC model receiver does not require a battery. The receiver can be installed by first plugging the short extension cord into the fireplace receptacle. Then plug the receiver unit into the extension cord. Finally plug the ignition module plug into the receiver unit (see Figure 46).

3.Activate the remote handset battery by removing the insulating tab on the back of the handset (see Figure 47). The battery is included pre-installed.

4.Once the battery is activated the unit is ready to use.

5.Close lower louver panel.

Fireplace

 

Receptacle

Remote Control

 

 

Receiver

Extension Cord

Ignition

Module Plug

 

Figure 46 - Installing the WRC Remote Receiver

optional Remote controlBattery Cover

12 Volt Battery

Back of

Pull to Remove

Handset

Insulation Tab

Figure 47 - Installing Battery into Back of Handset

INCOMING MAIN

GAS SUPPLY

EV1

EV2

GAS LINE TO

BURNER

Wiring Diagram

Pilot Burner

WALL SWITCH (SUPPLIED)

Pilot Gas

 

 

ON

OFF

 

Line

 

 

 

 

 

 

 

 

 

 

 

 

BLACK

INCOMING

 

 

 

 

 

MV

 

 

 

WHITE

120V AC

 

MODEL SP745 IGNITION CONTROL

 

 

GREEN

(FUSE BOX

TH PV/MV TR GND PV

Robertshaw

 

OR BREAKER)

BLACK WHITE GREEN

 

 

IGN

 

 

 

 

 

ELECTRICAL RATING: 120v, 60Hz, 0.7A

24V AC

STEP DOWN

TRANSFORMER

120V AC

OPTIONAL

REMOTE

CONTROL