OPERATING FIREPLACE

Normal Lighting Instructions To Turn Off Gas To Appliance

25

OPERATING FIREPLACE

Continued

NORMAL LIGHTING INSTRUCTIONS

WARNING: You must operate this heater with the fireplace screen in place. Make sure fireplace screen is in place before running heater.

NOTICE: During initial operation of new heater, burning logs will give off a paper-burning smell. Open damper or window to vent smell. This will only last a few hours.

1.STOP! Read the safety information, page 24, column 2.

2.Make sure equipment shutoff valve is fully open.

3.Wait five (5) minutes to clear out any gas. Smell for gas around heater and near floor. If you smell gas, STOP! Fol- low “B” in the safety information on warnings plate. If you don’t smell gas, go to the next step.

A. Using Supplied Wall Switch

1.Set manual ignition bypass switch on the control panel to the OFF position (automatic ignition position).

2.Press ON/OFF button. Hold for 6 seconds. Gas valve will open and electronic ignition will begin sparking to light pilot. LED will light. Note: You may be running this heater for the first time after connecting to gas supply or at the start of your heating season. If so, the ON/OFF button may need to be pressed again. This will allow air to bleed from gas system. If several attempts to light pilot fail, contact a qualified service person or gas supplier for repairs. Until repairs are made, light and operate manually (see Manual Lighting Instructions for Electric Power Outage, page 26).

3.When pilot flame is lit, the thermocouple is heated by the flame. When thermocouple becomes hot (5 to 15 seconds), main burner will automatically light on high flame.

4.To lower flame, push HI/LO button on wall switch once. Note: This fireplace does not have a pilot-only mode.

CAUTION: Do not try to adjust heating levels by using the equipment shutoff valve.

Manual Ignitor

 

Manual Ignitor

Electrode

Automatic

Pilot

Electrode

Automatic

 

Pilot

Ignitor

Burner

 

Ignitor

Burner

Electrode

 

 

Electrode

Figure 56 - Pilot (Natural Gas) Figure 57 - Pilot (Propane/LP Gas)

B. Using Hand-Held Wireless Remote Control

1.Set manual ignition bypass switch on control panel to OFF position (automatic ignition position).

2.Wait five (5) minutes to clear out any gas. Smell for gas around heater and near floor. If you smell gas, STOP! Fol- low “B” in the safety information on warnings plate. If you don’t smell gas, go to the next step.

3.Point remote control toward the lower front of fireplace and push both buttons at the same time. Hold for 6 sec- onds. The gas valve will open and electronic ignition will begin sparking to light the pilot. Note: You will be able to hear a clicking sound during this process. LED on wall switch will light.

Note: You may be running this heater for the first time after connecting to gas supply or at the start of your heat- ing season. If so, the ON button may need to be pressed again. This will allow air to bleed from gas system. If sev- eral attempts to light pilot fail, contact a qualified service person or gas supplier for repairs. Until repairs are made, light and operate manually (see Manual Lighting Instruc- tions for Electrical Power Outage, page 26).

4.When pilot flame is lit, the thermocouple is heated by the flame. When thermocouple becomes hot (5 to 15 seconds), main burner will automatically light on high flame.

5.To lower flame, point remote control toward lower front of fireplace and push HI/LO button once.

Note: This fireplace does not have a pilot-only mode.

TO TURN OFF GAS TO APPLIANCE

Manual Ignition Bypass Switch (Up is for Remote Control)

 

MANUAL

 

 

IGNITION

ON/OFF Button

HI/LO

 

 

 

Button

ON OFF

Wall

HI LO

 

 

Switch

 

LED

 

Figure 55 - Control Locations

Shutting Off Heater - Wall Switch

Push ON/OFF button on wall switch once.

Shutting Off Heater - Wireless Remote Control

Point remote control toward lower front of fireplace and push both buttons at the same time.

For morevisit www..com

108117

Page 25
Image 25
Desa VTGF33PR, VTGF33NR, CGEFP33PR installation manual Normal Lighting Instructions, To Turn OFF GAS to Appliance

VTGF33NR, CGEFP33PR, VTGF33PR specifications

Desa VTGF33PR, CGEFP33PR, and VTGF33NR are innovative heating solutions designed to enhance comfort and provide efficient warmth in various living spaces. These products are particularly popular for their advanced features, energy efficiency, and usability.

The Desa VTGF33PR is a natural gas vent-free infrared heater that showcases a sleek design and powerful performance. One of its standout features is its infrared technology, which allows for direct heating by warming surfaces in the room rather than just the air. This results in faster warmth and efficient energy use. The VTGF33PR also comes equipped with a thermostat, ensuring optimal temperature regulation and control over heating preferences. With a heating capacity of 33,000 BTUs, it is suitable for larger areas, providing consistent and reliable warmth even in larger spaces.

Moving on to the CGEFP33PR, this model operates on propane and combines both elegance and efficiency. This direct vent fireplace offers a unique balance between aesthetics and performance. The CGEFP33PR features a contemporary design, making it a stylish addition to modern homes. With its high-efficiency venting system, it ensures that combustion gases are safely expelled outside while maximizing heat output into the living space. It also showcases an adjustable flame feature, allowing users to set their desired ambiance while maintaining energy efficiency. Like the VTGF33PR, it includes a thermostat control for precise temperature adjustments.

Finally, the VTGF33NR is another noteworthy entry in Desa’s lineup. It operates similarly to the VTGF33PR, with a focus on infrared heating. However, the VTGF33NR distinguishes itself with its impressive portability and versatility. It is designed to be easy to install and relocate, making it a perfect choice for both homeowners and renters. Its space-saving design allows it to fit seamlessly into various room setups. This model also boasts a robust safety feature set, including an oxygen depletion sensor and an automatic shut-off mechanism, ensuring safe operation in any environment.

In summary, Desa’s VTGF33PR, CGEFP33PR, and VTGF33NR present a range of heating solutions that prioritize energy efficiency, safety, and user comfort. With advanced technologies such as infrared heating and sleek designs, these models stand out as practical solutions for any home looking to enhance its heating capabilities while maintaining modern aesthetics.