OPERATING FIREPLACE

Continued

NORMAL LIGHTING

INSTRUCTIONS

WARNING: You must oper- ate this heater with the fireplace screen in place. Make sure fire- place screen is in place before running heater.

NOTICE: During initial operation of new heater, burning logs will give off a paper-burning smell. Open damper or window to vent smell. This will only last a few hours.

1.STOP! Read the safety information, page 21.

2.Make sure equipment shutoff valve is fully open.

3.Wait five (5) minutes to clear out any gas. Smell for gas around heater and near floor. If you smell gas, STOP! Follow “B” in the safety information on warnings plate. If you donʼt smell gas, go to the next step.

A. Using Supplied Wall Switch Assembly

1.Set manual ignition bypass switch on the control panel to the OFF position (auto- matic ignition position).

2.Press ON/OFF button. Hold for 6 seconds. Gas valve will open and electronic ignition will begin sparking to light pilot. LED will light. Note: You may be running this heater for the first time after connecting to gas sup- ply or at the start of your heating season. If so, the ON/OFF button may need to be pressed again. This will allow air to bleed from gas system. If several attempts to light pilot fail, contact a qualified service person or gas supplier for repairs. Until repairs are made, light and operate manually (see Manual Lighting Instructions for Electric Power Outage, page 19).

3.When pilot flame is lit, the thermocouple is heated by the flame. When thermocouple becomes hot (5 to 15 seconds), main burner will automatically light on high flame.

4.To lower flame, push HI/LO button on wall switch once. Note: This fireplace does not have a pilot-only mode.

CAUTION: Do not try to ad- just heating levels by using the equipment shutoff valve.

HI/LO Button ON/OFF Button

Wall Switch

Assembly

LED

 

Manual Ignition Bypass Switch

(Up is for Remote Control)

Figure 37 - Control Locations

Thermocouple

Manual Ignitor

Electrode

 

Pilot

Burner

Automatic Ignitor

Electrode

Figure 38 - Pilot (Propane/LP Gas

Shown)

B.Using Hand-Held Wireless Remote Control

1.Set manual ignition bypass switch on control panel to OFF position (automatic ignition position).

2.Wait five (5) minutes to clear out any gas. Smell for gas around heater and near floor. If you smell gas, STOP! Follow “B” in the safety information on warnings plate. If you donʼt smell gas, go to the next step.

3.Point remote control toward the lower front of fireplace and push both buttons at the same time. Hold for 6 seconds. The gas valve will open and electronic ignition will begin sparking to light the pilot. Note: You will be able to hear a clicking sound during this process. LED on wall switch will light.

22

www.desatech.com

113134-01B

Page 22
Image 22
Desa VTGF33PRB Normal Lighting Instructions, Using Supplied Wall Switch Assembly, Using Hand-Held Wireless Remote Control

VTGF33NRB, VTGF33PRB specifications

Desa VTGF33PRB and VTGF33NRB are advanced heating solutions that combine innovative technology and design for optimal performance and user convenience. These models are well-suited for residential and commercial applications, providing efficient heating while enhancing the overall aesthetic of any space.

One of the main features of the VTGF33PRB and VTGF33NRB is their high-efficiency ratings, which allow them to deliver effective heating with minimal energy consumption. This efficiency not only helps users save on energy bills, but it also makes these models environmentally friendly, aligning with modern sustainability goals.

Both models utilize advanced infrared heating technology, which generates heat by directly warming objects and people in the room rather than heating the air. This results in a more comfortable and even distribution of warmth, providing immediate relief from cold temperatures. The infrared heating method is particularly beneficial in large or drafty spaces, as it can significantly reduce heating times and energy usage.

In terms of design, the VTGF33PRB features a sleek, modern appearance that can easily complement any décor. Its robust construction ensures durability, making it suitable for long-term usage. The VTGF33NRB, on the other hand, offers a more traditional aesthetic, perfect for those who prefer classic designs. Both models are user-friendly, designed with intuitive controls that allow for easy operation and temperature adjustments.

Another noteworthy characteristic of the Desa VTGF33 series is their safety features. Each unit is equipped with advanced safety mechanisms, including tip-over protection, overheat shut-off, and a sturdy base to prevent accidents. These safety features provide peace of mind for users, especially in households with children or pets.

The VTGF33PRB and VTGF33NRB also incorporate quiet operation technology, ensuring that heating is achieved without disruptive noise. This makes them ideal for use in bedrooms, offices, or any space where tranquility is desired.

Overall, the Desa VTGF33PRB and VTGF33NRB are exemplary models that showcase the harmonious blend of efficiency, safety, and design. Their advanced features and technologies make them reliable choices for anyone looking to enhance their heating solutions while maintaining comfort and style. With their commitment to quality and innovation, Desa continues to lead the way in the heating industry.