FIREPLACE INSTALLATION
Check Gas Type Installing Optional Blower Accessories
17
FIREPLACE INSTALLATION
.CHECK GAS TYPE
Use proper gas type for the fireplace unit you are installing. If you have conflicting gas types, do not install fireplace. See retailer where you purchased the fireplace for proper fireplace according to your gas type or to purchase gas conversion kit (see Accessories, page 39).
INSTALLING OPTIONAL BLOWER
ACCESSORIES
NOTICE: If installing blower in an existing fireplace with gas connections, shut off gas supply and dis- connect heater from gas supply. Contact a qualified service person to do this.
WARNING: If there is a duplex electrical outlet installed in the right side of the bottom of the fireplace base area, be sure that the electrical power to the outlet is turned off before proceeding with blower installation. Failure to do this may result in serious injury.
Model BK Installation
Follow all instructions provided in the blower accessory kit.
1.Attach the power cord to the blower motor by firmly pushing the two female terminals at the end of the power cord onto the two spade terminals on the blower motor (see Figure 25).
2.Attach green ground wire from power cord to blower housing using screw provided (see Figure 25). Tighten screws securely.
3.Place the blower against the lower rear wall of the firebox outer wrapper with the exhaust port directed upward. The blower will fit inside the back opening and be held in position against the back wall by the magnets (see Figure 25).
4.Be certain that all wire terminals are securely attached to ter- minals on blower motor and that the screw retaining the green ground wire is tight.
5.Mount speed control box to switch bracket by placing the plastic control shaft forward through the round opening in the switch bracket (see Figure 26).
| Blower | |
| Location | |
Lower Firebox |
| |
Cavity |
| |
Side View |
| |
Spade Terminals | Magnetic | |
Strips | ||
|
6.While supporting speed control, secure control shaft with lock nut by pushing and turning lock nut with pliers clockwise until it is tight against front panel. Place control knob provided on shaft.
7.Turn on power to duplex outlet if previously turned off per the warning in column 1.
8.Plug in blower power cord.
a.If your firebox is installed as a freestanding unit with an accessory mantel, determine whether the power cord will exit the left side or the right side of the firebox. Route power cord through exit hole and plug the power cord into a wall receptacle near the firebox.
b.If your firebox installation is recessed and/or
CAUTION: Never touch the blower wheel while in operation.
9.Check to make sure that the power cord is completely clear of the blower wheel and that there are no other foreign objects in blower wheel. Turn blower on and check for operation. Turn blower off by turning knob fully counterclockwise before continuing.
10.Peel off the backing paper and stick the supplied wiring dia- gram decal on the firebox bottom approximately 12" in front of the blower (see Figure 27).
Switch |
| Speed Control | |
Bracket |
| Blower | |
|
| ||
|
| ||
Control |
|
| |
Knob |
| Duplex Outlet | |
|
| (Located | |
Locknut | Control | underneath firebox | |
floor against lower | |||
| Shaft | ||
| right outside wall) | ||
|
|
Figure 26 - Attaching Speed Control to Firebox
Green Ground Wire | Wiring Diagram Decal |
12" in Front of Blower | |
Screw |
|
Exhaust Port | Figure 27 - Location of Wiring Diagram Decal (Model May Vary |
Figure 25 - Blower Model BK | From Illustration) |
For morevisit www..com