Chapter 2. Installation
61200420L1-1 ESU 120e User Manual 2-3
Code, ANSI/NFPA 70. Termination of the supplementary equip-
ment grounding conductor is permitted to be made to building
steel, to a metal electrical raceway system, or to any grounded item
that is permanently and reliably connected to the electrical service
equipment ground.
Bare, covered, or insulated grounding conductors are acceptable. A
covered or insulated grou nding conductor sh all have a contin uous
outer finish that is either green, or green with one or more yellow
stripes.
The supplemental grounding conductor shall be connected to he
equipment using a number 8 ring terminal. The terminal should be
fastened to the grounding lug provided on the rear panel of the
equipment. The ring terminal should be installed using the appro-
priate crimping tool (AMP P/N 59250 T-EAD Crimping Tool or
equivalent).