ADTRAN ESU 120e user manual Network NI Menu Items, Menu Item Description, Intface, CAS/TS16

Models: ESU 120e

1 124
Download 124 pages 62.06 Kb
Page 53
Image 53

Chapter 5. Configuration Menu

NETWORK (NI)

This menu item accesses the configuration of parameters associated with the network interface in the base unit. There are eight sub- menu items that include setting the format, the line build out (LBO), and the timing mode.

Network (NI) Menu Items

The menu items are:

Menu Item

Description

 

 

Interface

Selects either the 120Ω DB15 interface or the 75Ω BNC

(INTFACE)

interface.

 

Choices: 120Ω, 75Ω. BAL and 75Ω UNBAL

 

In 75Ω UNBAL mode, both the Tx and Rx are shield

 

grounded.

 

 

Framing

NFAS Word. If enabled, the network interface receiver

 

requires the NFAS word (TS0 in odd frames) and the FAS

 

word (TS0 in even frames) for frame sync. When disabled,

 

only the FAS word is needed for frame sync.

 

Choices: Enable, Disable

 

 

CAS/TS16

Enables/Disables Channel Associated signalling (time slot

 

16 multiframing). When this menu option is enabled, the

 

following occurs:

 

1. The TS16 multiframe alignment signal is inserted in the

 

outgoing data stream.

 

2. Signaling Bits are transmitted in TS 16 for all TS0s that are

 

mapped to a signalling-capable port (Base Drop port, for

 

example). In TS0s that are mapped to “Idle” or data ports,

 

“1s” are transmitted in the signalling bit positions.

 

3. The TS16 multiframe alignment signal must be received

 

for frame sync.

 

 

61200420L1-1

ESU 120e User Manual

5-3

Page 53
Image 53
ADTRAN ESU 120e user manual Network NI Menu Items, Menu Item Description, Intface, CAS/TS16