Chapter 4. Status Menu

If insufficient time has passed to collect data, NA displays. Con- tinue with standard operating procedures to exit the display.

When this menu is active, performance data can be cleared by pressing Clear (Shift 9) on the keypad. Only the user’s copy of the performance data is cleared.

Since only the user’s copy of performance data is cleared by the ESU 120e, the data displayed here might be different from the data sent to the network as PRM data.

Network Interface Errors (NI ERRORS)

The NI Errors submenu displays the types of errors the Network Interface (NI) detects. A blinking CSU error LED indicates that net- work errors are detected.

The asterisk (*) above an item indicates the type of errors detected. The error types are the following:

CRC CRC-4 bit errors. This is valid only if CRC-4 mode is enabled.

BPV Bipolar violations.

XS0 Excess zeros.

FER Framing errors.

Active Alarms

This menu item displays a list of current alarms reported by either the base controller or any of the ports. If no alarms are current, using this menu item displays End of List.

This display includes two lines of text. The top line is the alarm source. The bottom line is the alarm message. A list of alarm mes- sages is found in the appendix, ESU 120e System Messages.

61200420L1-1

ESU 120e User Manual

4-3

Page 47
Image 47
ADTRAN ESU 120e user manual Network Interface Errors NI Errors, Active Alarms