Chapter 7. Test Menu

Port Test Menu Items for 0.1 Nx56/ 64

0.1Nx56/64 is the base Nx interface. It offers the following test functions:

LOOPBK

This initiates a loopback. The following options are available:

PRT/LCL

The Nx port activates both a Local loopback (back

 

toward the DTE) and a Port loopback when either is

 

invoked.

REMOTE

The remote loopback causes a V.54 code to be sent to

 

the far end. The Nx at the far end activates a PRT/LCL

 

loopback upon detection of the V.54 code.

OFF

The loop is deactivated.

The ESU 120e checks the remote loopback activation by detecting a proper response from the remote end. While waiting for the re- sponse, the display shows Looping. If successful, the display changes to Looped -Up. If unsuccessful, the display shows Failed.

511 PATT

Activates the generation of the 511 test pattern.

ON

The pattern check circuitry is enabled and a test started.

 

The test is ended by selecting OFF.

OFF

The pattern generation and check is disabled.

D IS 511 RESLT

Displays the results of the 511 test indicated in the 511 option. The results are in the form of the number of errored seconds. The error count can be cleared by pressing the Clear key (shift+9).

7-8

ESU 120e User Manual

61200420L1-1

Page 84
Image 84
ADTRAN ESU 120e user manual Port Test Menu Items for 0.1 Nx56, Prt/Lcl, Remote, Patt