4
PRODUCT FEATURES
Location and Space Requirements
PRODUCT FEATURES
These are a few facts that can help you understand and enjoy your
•The venting system may be routed to the outside of your home in several ways. It may vent through the roof (vertical) or it may vent to an outside/exterior wall (horizontal). The vent pipe instal- lation is very important to allow for proper operation. You must follow the venting instructions very carefully for either vertical or horizontal applications.
•This fireplace may be installed in any room of your house provided all local codes and these installation instructions are followed.
•This fireplace requires a wall switch,
•This fireplace does not require electricity to operate.
•Only the blower requires electricity if installed and if you plan to install the blower at a later date, do not forget to wire the outlet at the bottom of the fireplace when framing.
•A piezo ignitor and ceramic electrode create spark to ignite the pilot light. It does not require any matches, batteries or any other sources of ignition to light the pilot.
•Each time you turn on your fireplace, you may notice some amount of condensation on the inside of the fireplace glass. This is normal and will disappear after
•Your
•Fireplaces with the suffix of
•Your fireplace is designed to be used in zero clearance instal- lations. Wall or framing material can be placed directly against any exterior surface on the back, sides or top of your fireplace, except where standoff spacers are integrally attached. If standoff spacers are attached to your fireplace, these spacers can be placed directly against wall or framing material. See framing details on page 5.
•If you plan on installing a television or entertainment center re- cessed above your fireplace, it is recommended that you maintain a minimum 18" above top of louver opening.
•When locating termination cap, it is important to observe the minimum clearances shown in Figure 7, page 6.
•If recessing into a wall, you can avoid extra framing by position- ing your fireplace against an already existing framing member.
•Do not recess termination cap into a wall or siding.
•You may paint the termination cap with 450ºF (232ºC) heat- resistant paint to coordinate with the exterior finish.
•There must not be any obstruction such as bushes, garden sheds, fences, decks or utility buildings within 24" from the front of the termination cap.
•Do not locate termination cap where excessive snow or ice build up may occur. Be sure to clear vent termination area after snow falls to prevent accidental blockage of venting system. When using snow blowers, do not direct snow towards vent termination area.
PRE-INSTALLATION
PREPARATION
LOCATION AND SPACE REQUIREMENTS
Determine the safest and most efficient location for your DESA
When deciding the location of your fireplace, follow these rules:
•Do not connect this fireplace venting to a chimney flue serving a separate
•Due to high temperatures, do not locate this fireplace in high traffic areas, windy or drafty areas or near furniture or draperies.
•Proper clearances must be maintained.
•If your fireplace is to be installed directly on carpeting, vinyl tile or any combustible material other than wood, it must be installed on a metal or wood panel extending the full width and depth of the fireplace. See Figure 3.
Flush with a wall |
| |
Through exterior wall | Corner | |
enclosed in a chase | ||
installation | ||
|
Figure 2 - Common Fireplace Locations
36 1/4"
23 1/4"
48"
Figure 3 - Fireplace Bottom Dimensions
www.desatech.com |