® VENTED GAS LOGS

OPERATING

APPLIANCE

Continued

CURING LOGS

During the 2-3 hour appliance break-in period, you may detect an odor from the appliance as the various paints and com- pounds used in the manufacturing of this log set cure. This is a normal and tempo- rary situation that is not cause for alarm. However, you may want to provide extra ventilation to the room during this time.

To ensure proper curing of the logs:

Ignite a 2" flame and maintain it for 1 hour.

Burn the logs in consecutive 1 hour pe- riods raising the flame an additional 2" to full flame height for a total of three hours.

OPTIONAL REMOTE

OPERATION

Note: All remote control accessories must be purchased separately. Follow instruc- tions included with the remote control.

NOTICE: You must light the pilot before using the hand-held re- mote control unit. See Lighting Instructions.

1.After lighting, let pilot flame burn for about one minute. Turn control knob to ON position. Slide the selector switch to the REMOTE position. NOTE: The burner may light if hand-held remote ON button was on when selector switch was last turned off. You can now turn the burner on and off with the hand- held remote control unit.

IMPORTANT: Do not leave the se- lector switch in the REMOTE posi- tion when the pilot is not lit. This will drain the battery.

IMPORTANT: Be sure to press the ON/OFF buttons on the hand-held remote control unit for up to 3 sec- onds to assure proper operation.

GHRC Operation:

2.Press the ON/OFF button to turn the burner on and off. When turning burner off, the pilot will remain lit.

GWMS2 WALL

MOUNTED SWITCH

(OPTIONAL)

This wall switch works just like the con- ventional light switch. Flip the switch up for on and down for off.

Note: Make sure that this switch is not in a position to be mistaken for a light switch. This may result in the log set being inad- vertently turned on without the proper precautions being taken. See installation instructions on page 11 of this manual.