OWNER’S MANUAL
TROUBLESHOOTING
Continued
WARNING: If you smell gas
•Shut off gas supply.
•Do not try to light any appliance.
•Do not touch any electrical switch; do not use any phone in your building.
•Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
•If you cannot reach your gas supplier, call the fire department.
IMPORTANT: Operating log set where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors. These odors will disappear over time.
OBSERVED PROBLEM | POSSIBLE CAUSE | REMEDY |
Log Set produces a clicking/ticking noise just after burner is lit or shut off
1.Metal expanding while heating or con- tracting while cooling
1.This is common with most log sets. If noise is excessive, contact qualified ser- vice person
Log Set produces unwanted odors | 1. | Log Set burning vapors from paint, hair |
|
| spray, glues, cleaners, chemicals, new |
|
| carpet, etc. (See IMPORTANT state- |
|
| ment above) |
| 2. | Gas leak. See Warning statement at |
|
| top of page |
1.Open flue to maximum. Stop using odor causing products while log set is running
2.Locate and correct all leaks (see Check- ing Gas Connections, page 8)
Gas odor even when control knob is in OFF | 1. | Gas leak. See Warning statement at | 1. | Locate and correct all leaks (see Check- |
position |
| top of page |
| ing Gas Connections, page 8) |
| 2. | Control valve defective | 2. | Replace control valve |
|
|
|
|
|
Gas odor during combustion | 1. | Gas leak. See Warning statement at | 1. | Locate and correct all leaks (see Check- |
|
| top of page |
| ing Gas Connections, page 8) |
www.desatech.com
901272 | 17 |