OWNER’S MANUAL

OPERATING

APPLIANCE

Continued

LIGHTING

INSTRUCTIONS

1.STOP! Read the safety information, page 12 column 3.

2.Make sure manual shutoff valve is fully open.

3.If Using Optional Hand-Held Re- mote or Wall Switch: Set switch to OFF position.

WARNING: Burner will come on automatically within one minute when the selector switch is in the ON position after the pilot is lit.

4.Press in and turn control knob clock-

wise to the OFF position.

5.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety in- formation, page 12 column 3. If you don’t smell gas, go to the next step.

6.Press in and turn control knob coun-

terclockwise to the PILOT position. Press in control knob for five (5) seconds (see Figure 23).

Note: You may be running this log set for the first time after hooking up to gas supply. If so, the control knob may need to be pressed in for 30 sec- onds or more. This will allow air to bleed from the gas system.

7.With control knob pressed in, press and release ignitor button. This will light pilot. If needed, keep pressing ignitor button until pilot lights.

Note: If pilot does not stay lit, contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure.

8.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

If control knob does not pop out when released, contact a qualified service person or gas supplier for repairs.

Note: If pilot goes out, repeat steps 4 through 8.

9.Slightly push in and turn control

knob counterclockwise to the ON position.

10.If Using Optional Hand-Held Re- mote or Wall Switch: Wait one minute and switch selector switch to the ON position to light burner.

Igniter

Button

Control

Knob

 

 

O

 

 

F

N

 

F

O

 

P

 

I

 

TOL

 

Figure 23 - Control Knob and Ignitor But- ton Location (Shown as Supplied, No Control Options)

Ther-

Pilotmopile

Figure 24 - Thermopile and Pilot

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Appliance

1.Slightly push in and turn control

knob clockwise to the OFF position.

Shutting Off Burner Only (pilot stays lit)

You may shut off the burner and keep the pilot lit by doing one of the following:

1.Slightly push in and turn control

knob clockwise to the PI- LOT position.

2.If Using Optional Hand-Held Re- mote or Wall Switch: Set switch to OFF position.

MANUAL LIGHTING

PROCEDURE

1.Follow steps 1 through 6 under Light- ing Instructions.

2.Depress control knob and light pilot with match.

3.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Now follow steps 9 through 10.

Continued

901272

13

Page 13
Image 13
Desa VVDA24R Lighting Instructions, To Turn OFF GAS To Appliance, Manual Lighting Procedure, Shutting Off Appliance