Desa VYGF33NR To Turn Off Gas To Appliance, Optional Remote Operation, Manual Lighting Procedure

Models: VYGF33NR

1 28
Download 28 pages 684 b
Page 15
Image 15
TO TURN OFF GAS

OWNER’S MANUAL

OPERATING

FIREPLACE

Continued

OPTIONAL REMOTE WARNING: Make sure the re- mote selector switch is in the OFF position when you are away from home for long periods of time. Heater will come on auto- matically with remote selector switch in the ON position.

Pilot Burner

Ignitor Electrode

Figure 26 - Pilot

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Heater

OPTIONAL REMOTE

OPERATION

Note: All remote control accessories must be purchased separately (see Accessories, page 21). Follow instructions included with the remote control.

Thermostat Control Operation

(Optional GHRCT Only) The thermo- stat control setting on the remote control unit can be set to any comfort level be- tween HI and LO. The Burners will turn on and off automatically to maintain the comfort level you select. The ideal com- fort setting will vary by household de- pending upon the amount of space to be heated, the output of the central heating system, etc.

For wall thermostat operation, follow in- struction supplied with thermostat ac- cessory GWMT1. For wall switch opera- tion follow instructions supplied with GWMS2.

NOTICE: You must light the pilot before using the hand-held re- mote control unit. See Lighting Instructions on page 14.

1.After lighting, let pilot flame burn for about one minute. Turn control knob to ON position. Adjust flame adjust- ment knob anywhere between HI and LO. Slide the remote selector switch to the REMOTE position (see Figure 27). The burners will come on. You can now turn the burners on and off with the hand-held remote con- trol unit.

IMPORTANT: Do not leave the re- mote selector switch in the RE- MOTE position when the pilot is not lit. This will drain the battery.

GHRC Operation:

2.Press the ON button to turn the burners on and the Off button to turn the heater to pilot.

GHRCT Operation:

2.Select the MANUAL or AUTO but- ton on the hand-held remote control unit (GHRCT only, see Figure 28).

In MANUAL mode, turn burners on or off by pressing the ON or OFF buttons on the hand-held re- mote control unit. (This is the only function with GHRC.)

1.Turn control knob clockwise MANUAL LIGHTING to the OFF position.

2.Set remote selector switch in the OFF position.

Shutting Off Burners Only (pilot stays lit)

You may shut off the burners and keep the pilot lit by doing one of the following:

• Turn control knob clockwise

Flame Adjustment Knob

 

IH

 

P

 

 

F

IL

 

 

 

O

 

 

F

 

T

 

 

O

 

 

 

 

 

 

 

 

 

O

 

 

 

 

N

ON

 

 

 

 

LO

 

 

 

OFF

REMOTE

Control Knob in

to the PILOT position.

• Use remote control manual OFF button.

On Position

Remote Selector Switch in Remote Position(Optional Remote Control)

• Set remote selector switch in the OFF

position.

Figure 27 - Setting the Remote Selector Switch, Control Knob, and Flame Adjustment Knob for Remote Operation

MANUAL LIGHTING

PROCEDURE

1.

Follow steps 1 through 6 under Light-

 

ing Instructions, page 14.

2.

Depress control knob and light pilot

 

with match.

3.

Keep control knob pressed in for 30

 

seconds after lighting pilot. After 30

 

seconds, release control knob. Now

Shows Temperature Setting

Allows Burners to be Turned On and Off with the Hand-Held Remote Unit.

The log heater will automatically cycle between pilot and the heat setting that has been selected.

HI

TEMP

MAN LO ON

AUTO OFF

STATUS

Increases Room Temperature

Decreases Room Temperature

Turns Burners On and Off

Shows Current Operation Mode

follow step 9.

Figure 28 - Thermostat Hand-Held Remote Control Unit Selections

Continued

104352

15

Page 15
Image 15
Desa VYGF33NR To Turn Off Gas To Appliance, Optional Remote Operation, Manual Lighting Procedure, Operating Fireplace