Manitowoc Ice Q130 Section Maintenance, Interior Cleaning and Sanitizing, B. Remove Water Pump

Models: Q130

1 40
Download 40 pages 32.69 Kb
Page 23
Image 23
Section 4

Section 4

Maintenance

Interior Cleaning and Sanitizing

GENERAL

Clean and sanitize the ice machine every six months for efficient operation. If the ice machine requires more frequent cleaning and sanitizing, consult a qualified service company to test the water quality and recommend appropriate water treatment.

The ice machine must be taken apart for cleaning and sanitizing.

!Caution

Use only Manitowoc approved Ice Machine Cleaner (part number 94-0546-3) and Sanitizer (part number 94-0565-3). It is a violation of Federal law to use these solutions in a manner inconsistent with their labeling. Read and understand all labels printed on bottles before use.

CLEANING AND SANITIZING PROCEDURE

!Caution

Do not mix Ice Machine Cleaner and Sanitizer solutions together. It is a violation of Federal law to use these solutions in a manner inconsistent with their labeling.

!Warning

Wear rubber gloves and safety goggles (and/or face shield) when handling Ice Machine Cleaner or Sanitizer.

Ice machine cleaner is used to remove lime scale and mineral deposits. Ice machine sanitizer disinfects and removes algae and slime.

Step 1 Set the toggle switch to the OFF position after ice falls from the evaporator at the end of a Harvest cycle. Or, set the switch to the OFF position and allow the ice to melt off the evaporator.

!Caution

Never use anything to force ice from the evaporator. Damage may result.

Step 2 Remove all ice from the bin.

Step 3 To start a cleaning cycle, move the toggle switch to the WASH position.

Step 4 Add the proper amount of Manitowoc Ice Machine Cleaner to the water trough.

Model

Amount of Cleaner

Q130

1 ounces (30 ml)

Q210

2 ounces (60 ml)

Q270

2 ounces (60 ml)

Step 5 Wait until the clean cycle is complete (approximately 22 minutes) then place the toggle switch in the OFF position, disconnect power and water supplies to the ice machine.

!Warning

Disconnect electric power to the ice machine at the electric switch box before proceeding.

Step 6 Remove parts for cleaning.

A.Remove the Vinyl Hose

Disconnect the water hose from the distribution tube and water pump.

B.Remove Water Pump

Disconnect the water pump power cord.

DO NOT SOAK

WATER PUMP MOTOR IN

CLEANER OR SANITIZER

SOLUTIONS

Water Pump Removal

Loosen the screws securing the pump- mounting bracket to the bulkhead.

Lift the pump and bracket assembly off the mounting screws.

Part Number 000001130 12/08

4-1

Page 23
Image 23
Manitowoc Ice Q130 manual Section Maintenance, Interior Cleaning and Sanitizing, Cleaning And Sanitizing Procedure, General