Before Calling for Service

Before Calling for Service

 

Section 5

 

 

 

 

 

 

 

 

Problem

Possible Cause

To Correct

 

Ice machine produces shallow or

Ice thickness probe is out of adjustment.

Adjust the ice thickness probe.

 

incomplete cubes, or the ice

 

 

 

fill pattern on the evaporator is

Water trough level is to high or too low.

Check the water level.

 

incomplete.

 

 

 

Water float valve filter screen is dirty.

Remove and clean the filter screen.

 

 

Water filtration is poor.

Replace the filter.

 

 

Hot incoming water.

Connect the ice machine to a cold water

 

 

 

supply.

 

 

Water float valve is not working.

Remove the water float valve and clean it.

 

 

Incorrect incoming water pressure.

Water pressure must be 20-80 psi (137.9 -

 

 

 

551.5 kPA).

 

 

Ice machine is not level.

Level the ice machine.

 

Low ice capacity.

Water float valve filter screen is dirty.

Remove and clean the filter screen.

 

 

Incoming water supply is shut off.

Open the water service valve.

 

 

Water float valve stuck open or leaking.

Remove the water float valve and clean it.

 

 

The condenser is dirty.

Clean the condenser.

 

 

High air temperature around ice machine

Air temperature must not exceed 110°F

 

 

(air-cooled models).

(43.3°C).

 

 

Inadequate clearance around the ice

Provide adequate clearance.

 

 

machine.

 

 

 

Objects stacked around ice machine,

Remove items blocking airflow.

 

 

blocking airflow to condenser

 

 

 

(air-cooled models).

 

 

Safety Limit Feature

 

 

 

In addition to the standard safety controls, your Manitowoc ice machine features built-in safety limits that will stop the ice machine if conditions arise which could cause a major component failure.

Before calling for service, re-start the ice machine using the following procedure:

1.Move the ON/OFF/ WASH switch to OFF and then back to ON.

A.If the safety limit feature has stopped the ice machine, it will restart after a short delay. Proceed to step 2.

B.If the ice machine does not restart, see “Ice machine does not operate” on the previous page.

2.Allow the ice machine to run to determine if the condition is reoccurring.

A.If the ice machine stops again, the condition has reoccurred. Call for service.

B.If the ice machine continues to run, the condition has corrected itself. Allow the ice machine to continue running.

5-2