Electrical Service

Installation Instructions

Section 2

 

 

Electrical Service

GENERAL

!Warning

All wiring must conform to local, state and national codes.

VOLTAGE

The maximum allowable voltage variation is ± 10% of the rated voltage on the ice machine model/serial number plate at start-up (when the electrical load is highest).

The 115/1/60 ice machines are factory pre-wired with a 8’ power cord, and NEMA 5-15P-plug configuration.

The 208-230/1/60 and 230/50/1 ice machines are factory pre-wired with a 8’ power cord only, no plug is supplied.

FUSE/CIRCUIT BREAKER

A separate fuse/circuit breaker must be provided for each ice machine. Circuit breakers must be H.A.C.R. rated (does not apply in Canada).

!Warning

The ice machine must be grounded in accordance with national and local electrical codes.

Q130/Q210/Q270 ICE MACHINE

TOTAL CIRCUIT AMPACITY

The total circuit ampacity is used to help select the wire size of the electrical supply.

The wire size (or gauge) is also dependent upon location, materials used, length of run, etc., so it must be determined by a qualified electrician.

GROUND FAULT CIRCUIT INTERUPTER

Ground Fault Circuit Interrupter (GFCI/GFI) protection is a system that shuts down the electric circuit (opens it) when it senses an unexpected loss of power, presumably to ground. Manitowoc Ice, Inc. does not recommend the use of a GFCI/GFI circuit protection with our equipment. If code requires the use of a GFCI/GFI then you must follow the local code. The circuit must be dedicated, sized properly and there must be a panel GFCI/GFI breaker. We do not recommend GFCI/GFI outlets as they are known for more intermittent nuisance trips than panel breakers.

!Warning

PERSONAL INJURY POTENTIAL

If the supply cord is damaged, do not operate the equipment until the cord is replaced by a service agent or similarly qualified person..

 

Voltage

Air-Cooled

Water Cooled

Ice Machine

Phase

Maximum Fuse/

Total Amps

Maximum Fuse/

Total Amps

 

Cycle

 

Circuit Breaker

Circuit Breaker

 

 

 

 

 

 

 

 

 

 

115/1/60

15

7.0

15

6.3

 

 

 

 

 

 

Q130

208-230/1/60

15

3.1

15

2.6

 

 

 

 

 

 

 

230/1/50

15

3.0

15

2.5

 

 

 

 

 

 

 

115/1/60

15

6.5

15

6.1

 

 

 

 

 

 

Q210

208-230/1/60

15

3.6

15

3.1

 

 

 

 

 

 

 

230/1/50

15

3.6

15

3.1

 

 

 

 

 

 

Q270

115/1/60

15

10.7

15

9.9

 

 

 

 

 

Danfoss

208-230/1/60

15

5.2

15

4.7

Compressor

 

 

 

 

 

230/1/50

15

5.2

15

4.7

 

 

 

 

 

 

 

Q270

115/1/60

15

8.5

15

7.7

 

 

 

 

 

Tecumseh

208-230/1/60

15

4.5

15

4.0

Compressor

 

 

 

 

 

230/1/50

15

4.5

15

4.0

 

 

 

 

 

 

 

2-4