Section 4

Maintenance

 

 

Q130 Models

DISTRIBUTION

TUBE

THUMBSCREW

REMOVE ICE

THICKNESS PROBE

THUMBSCREW

Q130 Water Distribution Tube Removal

Loosen the two thumbscrews, which secure the distribution tube.

Lift the distribution tube up off the thumbscrews.

Disassembly

Twist the barbed end until the tab lines up with the keyway.

Pull the inner tube end outward.

TAB

KEYWAY

Q130 Water Distribution Tube Disassembly

E.Remove the Float Valve

Turn the splash shield counterclockwise one or two turns.

FLOAT VALVE

BRACKET

COMPRESSION

FITTING

SHUT-OFF VALVE

SPLASH SHIELD

CAP AND

FILTER SCREEN

FLOAT

Float Valve Removal

Pull the float valve forward and off the mounting bracket.

Disconnect the water inlet tube from the float valve at the compression fitting.

Remove the cap and filter screen for cleaning.

Part Number 000001130 12/08

4-3

Page 25
Image 25
Manitowoc Ice manual Q130 Models, Q130 Water Distribution Tube Removal, Float Valve Removal