Maintenance | Section 4 |
|
|
F. Remove the Water Trough | G. Remove the ice damper. |
• Apply downward pressure on the siphon tube and | Q130 |
remove from the bottom of the water trough. | • Grasp left side of ice damper and apply pressure |
| |
• Remove the upper thumbscrew. | against the |
• While supporting the water trough remove the two | • Pull forward on the ice damper until the |
thumbscrews from beneath the water trough. | mounting pin disengages. |
• Remove the water trough from the bin area. |
|
UPPER
THUMBSCREW
LOWER
THUMBSCREWS REMOVE SIPHON TUBE
Installation
•Grasp the right side of ice damper and place left hand pin in the mounting bracket.
•While applying pressure against the
Q210/Q270
•Grasp ice damper and apply pressure toward the left hand mounting bracket.
•Apply pressure to the right hand mounting bracket with thumb.
•Pull ice damper forward when the right hand ice damper pin disengages.
Installation
•Place ice damper pin in left hand mounting bracket and apply pressure toward the left hand mounting bracket.
•Apply pressure to the right hand mounting bracket with thumb.
•Push ice damper toward evaporator until right hand damper pin engages.
Part Number 000001130 12/08 |