Manitowoc Ice Q130 manual Energized Parts Chart, Section, Operation

Models: Q130

1 40
Download 40 pages 32.69 Kb
Page 19
Image 19
Energized Parts Chart

Section 3

 

 

 

 

 

 

Operation

 

 

 

 

 

 

 

 

Energized Parts Chart

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CONTROL BOARD RELAYS

 

RELAY

 

 

 

1

2

3

3A

 

3B

LENGTH

 

 

WATER

HOT GAS

RELAY

COMPRESSOR

 

CONDENSER

of “ON” TIME

 

 

PUMP

VALVE

COIL

 

FAN MOTOR

 

 

 

 

 

INITIAL START-UP/

 

 

 

 

 

 

 

START UP AFTER

 

 

 

 

 

 

15

AUTO SHUT-OFF:

OFF

ON

OFF

OFF

 

OFF

 

 

 

Seconds

 

 

 

 

 

 

 

 

1. Pressure

 

 

 

 

 

 

 

Equalization

 

 

 

 

 

 

 

2. Refrigeration

OFF

ON

ON

ON

 

ON

5

System Start-up

 

Seconds

 

 

 

 

 

 

FREEZE

 

 

 

 

 

 

 

SEQUENCE:

OFF

OFF

ON

ON

 

ON

30

 

 

 

Seconds

 

 

 

 

 

 

 

 

3.

Pre-Chill

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Until 7 sec.

 

 

 

 

 

 

 

 

water contact

4.

Freeze

ON

OFF

ON

ON

 

ON

with ice

 

 

 

 

 

 

 

 

thickness

 

 

 

 

 

 

 

 

probe

 

 

 

 

 

 

 

 

HARVEST

 

 

 

 

 

 

 

SEQUENCE:

OFF

ON

ON

ON

 

ON

Bin switch

 

 

 

activation

 

 

 

 

 

 

 

 

5.

Harvest

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AUTOMATIC SHUT-

 

 

 

 

 

 

Until

 

OFF:

 

 

 

 

 

 

 

OFF

OFF

OFF

OFF

 

OFF

bin switch

 

 

 

6. Auto Shut-Off

 

 

 

 

 

 

re-closes

 

 

 

 

 

 

 

* Condenser Fan Motor: The fan motor is wired through a fan cycle pressure control, therefore, it may cycle on and off.